User manual
24 Wide Bank 28 DS3 - Release 2.4
E1 Circuit Configuration
E1 Circuit Configuration
1. Retrieve Current E1 Configuration
RTRV-E1:tid:aid:ctag;
Example: Retrieve configuration for E1 #1.
RTRV-E1:tid:E1-01:ctag;
Response: tid 2001-08-04
11:47:18
M ctag COMPLD
"E1-01::AISF=Y,CMDMDE=FRCD,DLCID=E1 1,
FLMDE=BOTH,FMT=UNFR,IDLE=AIS,LINECDE=HDB3,
OMODE=NORM,RVRTFLAG=UNLCKD:IS-EQ,NALMNR"
;
2. Determine E1 Configuration Choices
3. To Edit E1 Configuration
ED-E1:tid:aid:ctag:::[DLCID=dlcid],[OMODE=omode];
Example: Set E1 #3 Circuit ID to WB6-E1-03.
ED-E1:tid:E1-03:ctag:::DLCID=WB6-E1-03;
4. To Enter E1 Configuration and Put In Service
ENT-E1:tid:aid:ctag:::[DLCID=dlcid],[OMODE=omode];
Example:
Create E1 #3 with Circuit ID set to WB6-E1-03 and place in service.
ENT-E1:tid:E1-03:ctag:::DLCID=WB6-E1-03;
If PST= Your choice is
IS-EQ
IS-RLY
IS-UEQ
Edit a parameter while in service.
ED-E1:tid:aid:ctag:::[DLCID=dlcid],[OMODE=omode];
Place a facility out of service.
RMV-E1:tid:aid:ctag;
OOS-EQ
OOS-RLY
OOS-UEQ
Edit a parameter while out of service
ED-E1:tid:aid:ctag:::[DLCID=dlcid],[OMODE=omode];
Enter (grow) a facility and place in service (ENT-E1)
RMV-E1:tid:aid:ctag;
AIDType AID
E1 E1-01 to E1-27, or ALL
(see T3-E1 Configuration
AIDs on page 8)
PST