T3 Protection and Revertive Configuration
T3 Protection and Revertive Configuration
The following steps show how to retrieve the current DS3 equipment configuration and condition, and how to
change the DS3 protection and revertive properties. The unit can also provide automatic protection switching
(APS) if it has two DS3 lines as well as two DS3 controller cards.
1. Retrieve Current T3 Equipment Configuration
This will show the status of the DS3 controller cards and whether the unit can provide high-speed protection.
RTRV-EQPT:tid:[ALL]:ctag;
Example: RTRV-EQPT:tid:ALL:ctag;
Response: tid 2001-08-04 05:08:45
T3 Equipment Status Values
Equipment Status Description
DS3 -A, DS3-B Active Controller card is installed and in active mode (DS3 circuit
is active)
Standby Controller is installed and in standby mode
Not Present Controller is not installed
Not Ready Controller is present, but is not communicating with the
active card for unknown reasons
Fail Controller hardware failure
M ctag COMPLD
"DS3-A:ACTIVE,2.40.0"
"DS3-B:STANDBY,2.40.0"
"DS1-CARD-1:ACTIVE,"
"DS1-CARD-2:ACTIVE,"
"DS1-CARD-3:ACTIVE,"
"DS1-CARD-4:ACTIVE,"
"DS1-CARD-5:ACTIVE,"
"DS1-CARD-6:ACTIVE,"
"DS1-CARD-7:ACTIVE,"
"DS1-CARD-SPARE:ACTIVE,"
;
Status of DS3 controller cards.
Unit can provide high-speed
protection if one DS3 is ACTIVE
and one is STANDBY.