TITLE PAGE Wide Bank 28 DS3 TL1 JOB AID Fan Faceplate Option (FFO) Document: 002-0138-0100 Product Release: 2.
Copyright© 2003 Carrier Access Corporation. All rights reserved. The information presented in this manual is subject to change without notice and does not represent a commitment on the part of Carrier Access Corporation. The hardware and software described herein are furnished under a license or non-disclosure agreement. The hardware, software, and manual may be used or copied only in accordance with the terms of this agreement.
TABLE OF CONTENTS Communicating with the System n System Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 n Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 n Access Identifiers n Log-In/Log-Out Commands . . . . . . . . . . . . . . . . . . . . . . . 10 n Present State Definitions (PST) . . . . . . . . . . . . . . . . . . . . 13 .................................. 6 Configuration n System ID . . . . . . . . . . . . . .
System Overview System Overview Fan Faceplate Option (FFO) Carrier Access Corporation’s Wide Bank 28 DS3 Multiplexer provides a standards-based M13 multiplexing function with TL1 management. This product converts a framed Digital Signal Level 3 (DS3) network connection into 28 Digital Signal Level 1 (DS1) connections to T1 facilities, or into 21 connections to E1 facilities. Each Wide Bank 28 DS3 can be equipped with DS1 cards or E1 cards, but not both.
System Overview Maintenance Service Option (MSO) In addition to providing the same circuit failure protection as Standard DS1 and E1 cards, the MSO DS1 and E1 cards can be replaced without interrupting service on other circuits. The TL1 Access Identifiers clearly distinguish between standard cards and MSO cards. The MSO circuit card is made up of two separating sections called the MSO Electronics card and the MSO Relay card.
Guidelines Guidelines TL1 Command Syntax TL1 commands are not case sensitive and may be entered using “UPPER CASE” or “lower case” characters. For simplicity, this Job Aid uses the following conventions: l “UPPER CASE” characters denote Command words and Modifiers l “lower case” characters denote Keywords in commands and are accompanied by a table listing permissible values. Default values in the table are shown in bold type. l { } braces denote required keywords that must be present.
Guidelines l Retrieve the facility to verify parameters and present state l Retrieve the facility condition to verify normal operation (see Retrieve Condition on page 40) l Retrieve the facility alarms to verify normal operation (see Retrieve Alarms on page 41) Configure the next facility l Repeat the above items to configure each of the remaining facilities Test the facilities l Follow standard practices to test each facility l If desired, use the Diagnostics on page 32 and Loopbacks on page 34 Provisio
Access Identifiers Access Identifiers T3-T1 Configuration AIDs T1 AIDs DS1-01 DS1-02 DS1-03 DS1-04 DS1-05 DS1-06 DS1-07 DS1-08 DS1-09 DS1-10 DS1-11 DS1-12 DS1-13 DS1-14 DS1-15 DS1-16 DS1-17 DS1-18 DS1-19 DS1-20 DS1-21 DS1-22 DS1-23 DS1-24 DS1-25 DS1-26 DS1-27 DS1-28 6 Wide Bank 28 DS3 Quad DS1 Card Slot 1 A B C D Quad DS1 Card Slot 2 A B C D Quad DS1 Card Slot 3 A B C D Quad DS1 Card Slot 4 A B C D Quad DS1 Card Slot 5 A B C D Quad DS1 Card Slot 6 A B C D Quad DS1 Card Slot 7 A B C D Quad
Access Identifiers T3-T1 Equipment AIDs MSO only with Maintenance Service Option DS1-CARD-1 DS1-CARD-MS0-1 Wide Bank 28 DS3 Quad DS1 Card Slot 1 Fans only with Fan Faceplate Option (FFO) FAN-A DS1-CARD-2 DS1-CARD-MS0-2 Quad DS1 Card Slot 2 POWER-5V-A DS1-CARD-3 DS1-CARD-MS0-3 DS1-CARD-4 DS1-CARD-MS0-4 EXT48V-A Quad DS1 Card Slot 3 Quad DS1 Card Slot 4 DS3 Controller Card Slot A (Primary) POWER-5V-B DS1-CARD-5 DS1-CARD-MS0-5 EXT48V-B Quad DS1 Card Slot 5 DS1-CARD-6 DS1-CARD-MS0-6 Quad DS1 Car
Access Identifiers T3-E1 Configuration AIDs E1 AIDs E1-01 E1-02 E1-03 8 Wide Bank 28 DS3 Triple E1 Card Slot 1 T3 AIDs A B C E1-05 E1-06 E1-07 Triple E1 Card Slot 2 A B C E1-09 E1-10 E1-11 Triple E1 Card Slot 3 A B C E1-13 E1-14 E1-15 Triple E1 Card Slot 4 A B C E1-17 E1-18 E1-19 Triple E1 Card Slot 5 A B C E1-21 E1-22 E1-23 Triple E1 Card Slot 6 A B C E1-25 E1-26 E1-27 Triple E1 Card Slot 7 A B C Triple E1 Spare Slot A B C DS3 Controller Card Slot A (Primary) DS3-A DS3 Controlle
Access Identifiers T3-E1 Equipment AIDs MSO only with Maintenance Service Option E1-CARD-1 E1-CARD-MS0-1 Wide Bank 28 DS3 Triple E1 Card Slot 1 Fans only with Fan Faceplate Option (FFO) FAN-A E1-CARD-2 E1-CARD-MS0-2 Triple E1 Card Slot 2 POWER-5V-A E1-CARD-3 E1-CARD-MS0-3 E1-CARD-4 E1-CARD-MS0-4 EXT48V-A Triple E1 Card Slot 3 Triple E1 Card Slot 4 DS3 Controller Card Slot A (Primary) POWER-5V-B E1-CARD-5 E1-CARD-MS0-5 E1-CARD-6 E1-CARD-MS0-6 E1-CARD-7 E1-CARD-MS0-7 E1-CARD-SPARE E1-CARD-MSO-SP
Log-In/Log-Out Commands Log-In/Log-Out Commands 1. Activate User (Log In) NOTE: To simplify new installations, units are normally shipped with log-in security turned off unless the customer requests that it be turned on. When security is turned on, the default user name is ADMIN and the default password is either null or TEST. ACT-USER:tid:uid:ctag::pid; Keyword Description pid Private ID (password).
Log-In/Log-Out Commands 2. Edit PID (Change Password) ED-PID:tid:uid:ctag::old-pid,new-pid; Keyword Description uid User ID new-pid New Private ID (password). An ASCII string up to 10 characters long with at least two non-alphabetic characters with at least one special character. Null removes password requirement. Passwords are case-sensitive. old-pid Old Private ID (password) Example: ED-PID:tid:name:ctag::old-1,new-1; 3.
Log-In/Log-Out Commands 5. Set User Session Timeout This command is used by the system administrator to set the number of minutes before session inactivity timeout of the TL1 TCP/IP port. When the command is issued, any active sessions will be updated with the new session timeout period. Setting the tmout parameter to zero will turn off session inactivity timeouts so that sessions will never time out.
Present State Definitions (PST) Present State Definitions (PST) 1. Retrieve T3 Present State NOTE: The T3 facility’s Present State value is always in service and equipped (IS-EQ). RTRV-T3:tid:[aid]:ctag; Keyword Description aid Access ID (optional). If omitted, it will default to ALL. • ALL ctag Correlation Tag (optional) tid Target ID of network element (optional) Example: Retrieve current DS3 configuration.
Present State Definitions (PST) 2. Retrieve T1 or E1 Present State RTRV-T1:tid:aid:ctag; RTRV-E1:tid:aid:ctag; Keyword Description aid Access ID depends on facility type: • For T1 facility, use DS1-1 to DS1-28, or ALL • For E1 facility, use E1-01 to E1-27, or ALL (see T3-E1 Configuration AIDs on page 8) Note: This command supports aid lists and ranges (&, &&).
Present State Definitions (PST) PST and SST Values PST Keyword Description T1 and E1 facilities may have the following Primary State (PST) values.
System ID System ID The following steps show how to set the System ID (sid) that appears as in all TL1 messages and is required as the Target ID (tid) when used in TL1 commands. 1. Retrieve Current Equipment Configuration NOTE: The following command is executed automatically when the user logs in. RTRV-EQPT:tid:[ALL]:ctag; Example: RTRV-EQPT:tid:ALL:ctag; Response: M tid 2002-01-05 11:21:39 ctag COMPLD "DS3-A:ACTIVE,2.40.0" "DS3-B:STANDBY,2.40.
System Time of Day System Time of Day The following steps show how to reset the Wide Bank system clock. NOTE: The Wide Bank system clock must be reset after a power interruption. The clock date and time are used to time-stamp all alarms, events, and logs. Following a power interruption, the date and time will restart at 2001-01-01 01:00:00. 1. Retrieve Time of Day RTRV-TOD:tid::ctag; Example: RTRV-TOD:tid::ctag; Response: tid 2001-01-01 11:51:46 M ctag COMPLD "2001,01,01,11,51,46" ; 2.
T3 Circuit Configuration T3 Circuit Configuration The following steps show how to configure the T3 (DS3) facility. NOTE: The Wide Bank T3 facility is always In Service and Equipped (IS-EQ). 1. Retrieve Current T3 Configuration RTRV-T3:tid:[aid]:ctag; Keyword Description aid Access ID (optional). If omitted, it will default to ALL. • ALL Example: Retrieve the current DS3 configuration. RTRV-T3:tid:ALL:ctag; The following response shows the default configuration.
T3 Circuit Configuration T3 Configuration Parameters Keyword Description aid Access ID. Required for ED-T3 command. • ALL AISC= Specifies conditions on the input (receive) side of a connection under which AIS will be generated on the output (transmit) side of a connection. Hard-coded to LOS&AISNAS&LOF. AIST= Indicates the type of the AIS signal to be generated/transmitted, and the AIS signal mode expected on input should a failure condition exist. Hard-coded to ONES.
T3 Protection and Revertive Configuration T3 Protection and Revertive Configuration The following steps show how to retrieve the current DS3 equipment configuration and condition, and how to change the DS3 protection and revertive properties. The unit can also provide automatic protection switching (APS) if it has two DS3 lines as well as two DS3 controller cards. 1.
T3 Protection and Revertive Configuration 2. Retrieve Current T3 Condition RTRV-COND-T3:tid::ctag; Example: RTRV-COND-T3:tid::ctag; Response: M If T3:PROTNA appears, protection is not available, either because the second controller is not installed or has failed. tid 2001-08-04 05:05:51 ctag COMPLD "DS3-A,T3:PROTNA,NSA,,,,,,\"Protection Unit not Available\"" "DS3-A,T3:IHNSWPR,NSA,,,,,,\"DS3 Facility Protection not Enabled\"" "DS3-A,T3:INHAUTORSTEQPT,NSA,,,,,,\"DS3 Revertive Off\"" ; 3.
T1 Circuit Configuration T1 Circuit Configuration 1. Retrieve Current T1 Configuration RTRV-T1:tid:aid:ctag; AIDType AID T1 DS1-1 to DS1-28, or ALL Note: Most T1 commands support lists and ranges Example: Retrieve current configuration for DS1 #2. RTRV-T1:tid:DS1-02:ctag; Response: tid 2001-12-04 11:51:58 M ctag COMPLD "DS1-02::AISF=Y,CMDMDE=FRCD,DLCID=DS1 2, FLMDE=BOTH,FMT=UNFR,IDLE=AIS,LBO=1,LINECDE=B8ZS, OMODE=NORM,RVRTFLAG=UNLCKD:IS-EQ,NALMNR" ; PST 2.
T1 Circuit Configuration 5. To Remove T1 From Service CAUTION! REMOVING A T1 WILL DISRUPT SERVICE. RMV-T1:tid:aid:ctag; Example: Place DS1 #8 out of service. RMV-T1:tid:DS1-08:ctag; T1 Configuration Parameters Keyword Description AISF= Indicates whether failed signal from upstream should be replaced by AIS. Hardcoded to Y. CMDMDE= Indicates command execution mode. Hard-coded to FRCD. This means that existing parameter settings may be overridden in order to execute the command.
E1 Circuit Configuration E1 Circuit Configuration 1. Retrieve Current E1 Configuration RTRV-E1:tid:aid:ctag; Example: Retrieve configuration for E1 #1. AIDType AID E1 E1-01 to E1-27, or ALL (see T3-E1 Configuration AIDs on page 8) RTRV-E1:tid:E1-01:ctag; Response: tid 2001-08-04 11:47:18 M ctag COMPLD "E1-01::AISF=Y,CMDMDE=FRCD,DLCID=E1 1, FLMDE=BOTH,FMT=UNFR,IDLE=AIS,LINECDE=HDB3, OMODE=NORM,RVRTFLAG=UNLCKD:IS-EQ,NALMNR" ; PST 2.
E1 Circuit Configuration 5. To Remove E1 From Service CAUTION! REMOVING AN E1 WILL DISRUPT SERVICE. RMV-E1:tid:aid:ctag; Example: Place DS1 #3 out of service. RMV-E1:tid:E1-03:ctag; E1 Configuration Parameters E1 facilities are hardcoded to HDB3 line code and no line buildout. Keyword Description AISF= Indicates whether failed signal from upstream should be replaced by AIS. Hardcoded to Y. CMDMDE= Indicates command execution mode. Hard-coded to FRCD.
T1/E1 Protection and Revertive Configuration T1/E1 Protection and Revertive Configuration The following steps show how to retrieve the current T1/E1 equipment configuration and condition, and how to change the T1/E1 protection and revertive properties. 1. Retrieve Current T1/E1 Equipment Configuration This will show the status of the DS1/E1 spare card and whether the unit can provide circuit protection.
T1/E1 Protection and Revertive Configuration T1/E1 Equipment Status Values Equipment Status Description DS1/E1 Card Active DS1/E1 card is installed and active, but individual DS1/E1 circuits may have failed and be on Spare card Not Present DS1/E1 card is not installed MSO Active DS1/E1 MSO card (relay and electronics) is installed and active, but individual DS1/E1 circuits may have failed and be on Spare card MSO Relay Only Active on Spare DS1/E1 MSO relay card is installed, but electronics card
T1/E1 Protection and Revertive Configuration 2. Retrieve Current T1/E1 Condition RTRV-COND-T1:tid::ctag; RTRV-COND-E1:tid::ctag; Example: RTRV-COND-T1:tid:DS1-1:ctag; Response: M If T1:PROTNA or E1:PROTNA appears, protection is not available because the unit is not equipped with a spare card. tid 2001-08-04 05:05:51 ctag COMPLD "DS1-01,T1:INHAUTORSTEQPT,NSA,,,,,,\"DS1 Revertive Off\"" "DS1-01,T1:INHSWPR,NSA,,,,,,\"DS1 Facility Protection Not Enabled\"" ; 3.
T1/E1 Protection and Revertive Configuration 4. To Switch T1/E1 to Protection or Working Card The following commands will forcibly move a T1/E1 circuit between the protection (spare) and working (home) cards for testing or maintenance. Switching will be denied only if the equipment status (RTRVEQPT) of the other card is NOT PRESENT (not equipped) or UNKNOWN (equipped but status unknown). CAUTION! THESE COMMANDS MAY AFFECT SERVICE.
T1/E1 Auto In-Service Detection (LOS Inhibit) T1/E1 Auto In-Service Detection (LOS Inhibit) The following steps show how to use the Wide Bank’s automatic in-service detection feature to provision T1 or E1 circuits before facilities are available to properly terminate the circuits.
T1/E1 Auto In-Service Detection (LOS Inhibit) 2. Determine Automatic In-Service Choices Status Your choice is Auto In-Service is turned Off Turn on T1 automatic in-service detection and apply to T1s by placing T1s out of service and then back in service. 1. OPR-ARC-T1:tid::ctag; 2. RMV-T1:tid:aid:ctag; 3. ENT-T1:tid:aid:ctag; Turn on E1 automatic in-service detection and apply to E1s by placing E1s out of service and then back in service. 1. OPR-ARC-E1:tid::ctag; 2. RMV-E1:tid:aid:ctag; 3.
Diagnostics Diagnostics The following demonstrates how to perform self-test diagnostics. CAUTION! FACILITIES MUST BE REMOVED FROM SERVICE BEFORE DIAGNOSTICS CAN BE USED. DGN-T1 AND DGN-E1 WILL DISRUPT SERVICE ON THE SELECTED FACILITIES. DGN-T3 AND DGN-ALL WILL INTERRUPT SERVICE ON ALL FACILITIES. NOTE: A T3 can not actually be removed from service. The purpose of the RMV-T3 command is to allow the active T3 to be tested. 1.
Diagnostics Self-Test Diagrams LS = low speed card (DS1 or E1). HS = high speed controller card (DS3). T3 Self-Test DS1/E1 Relays Transceiver Selector LS Card M13 Framer Transceiver Relays DS3 HS Card Send AIS Send AIS Perform Self-Test Toward DS1/E1 Toward DS3 T1/E1 Self-Test DS1/E1 Relays LS Card Send AIS Toward DS1/E1 Wide Bank 28 DS3 - Release 2.
Loopbacks Loopbacks The following steps show how to perform various loopbacks. CAUTION! A LOOPBACK WILL AFFECT SERVICE. 1. Near-End Loop Code Detection The following commands allow or inhibit the detection of received NIU loop codes. The Wide Bank 28 DS3 responds only to line loop codes. Each T3, T1, and E1 facility has its own loop code pattern.
Loopbacks 2. Far-End Loopbacks The following commands connect or disconnect far-end loopbacks by sending code patterns to the far-end network element. NOTE: DS3 far-end loopbacks require the DS3 facility to be configured for C-bit framing.
Loopbacks 3. Near-End Loopbacks The following commands operate or release near-end loopbacks.
Loopbacks Near-End Looback Diagrams T3 Equipment Loopback DS1/E1 Transceiver Relays LS Card ASIC M13 Framer Transceiver Relays DS3 HS Card Loopback Toward DS1/E1 Send AIS Toward DS3 T3 Line Loopback DS1/E1 Transceiver Relays LS Card ASIC M13 Framer Transceiver Relays DS3 HS Card Send AIS Toward DS1/E1 Loopback Toward DS3 T3 Payload Loopback DS1/E1 Transceiver Relays LS Card ASIC M13 Framer Transceiver Relays DS3 HS Card Send AIS Toward DS1/E1 Loopback Toward DS3 T1/E1 Equipm
PM Reports PM Reports The following steps show how to configure and retrieve performance monitoring reports. 1.
PM Reports PM Report Parameters Keyword Description locn Location (optional): • NEND – near end and far end monlev Monitor Level (optional) specifies the discriminating level for the requested monitored parameter. The Wide Bank currently supports the following: • 1-UP – report all performance statistics that do not have a value of zero numrept The number of reports the user would like scheduled (optional). A value of zero turns reports off.
Retrieve Condition Retrieve Condition The following shows how to retrieve the current condition of a facility.
Retrieve Alarms Retrieve Alarms The following shows how to retrieve the current alarms for a facility.
Retrieve Logs Retrieve Logs The following shows how to retrieve the security and event logs for the Wide Bank 28 DS3. RTRV-LOG:tid:ALL:ctag::lognm; 42 Example Command Retrieve Security Log RTRV-LOG:tid:ALL:ctag::SECURITY; Retrieve Event Log RTRV-LOG:tid:ALL:ctag::EVT; Keyword Description lognm Name of Log. Values are: • SECURITY – Log where Security Events are Logged • EVT – Event Log Wide Bank 28 DS3 - Release 2.
Alarm and Event Message Parameters Alarm and Event Message Parameters Access Identifier Report Message Type Interface Type Default Notification Code * Service Condition Type or Condition Effect Code Condition Description DS3-{A,B} REPT ALM EQPT CR SA CONTEQPT Control Equipment Failure MN SA INT Internal Hardware Fault or Failure MJ NSA IMPROPRMVL Improper Removal CR SA TRMT Transmitter Failure MN NSA PROGFLT Software Version Mismatch Between Controllers CR SA LOS Loss of Sig
Alarm and Event Message Parameters Access Identifier Report Message Type Interface Type Default Notification Code * Service Condition Type or Condition Effect Code Condition Description DS3-{A,B} REPT ALM T3 MJ SA BER-SF Signal Fail MN NSA BER-SD Signal Degrade WKSWPR Working Unit Switched to Protect Unit WKSWBK Working Unit Switched Back to Working AISNAS Alarm Indication Signal - North American Standard RAI Remote Alarm Indication T-CVL Threshold Violation - CV Line T-CVP-P Thr
Alarm and Event Message Parameters Access Identifier Report Message Type Interface Type Default Notification Code * Service Condition Type or Condition Effect Code Condition Description DS1-{01-28} REPT ALM EQPT MN NSA INT Internal Hardware Fault or Failure REPT ALM T1 MN NSA BER-SD Signal Degrade MJ SA BER-SF Signal Fail MJ SA FAILTOSW Failed to Switch MJ SA LOS Loss of Signal T-CVL Threshold Violation - CV Line T-ESL Threshold Violation - Errored seconds line WKSWPR Wor
Alarm and Event Message Parameters Access Identifier Report Message Type Interface Type Default Notification Code * Service Condition Type or Condition Effect Code Condition Description E1-{01-27} REPT ALM EQPT MN NSA INT Internal Hardware Fault or Failure REPT ALM E1 MN NSA BER-SD Signal Degrade MJ SA BER-SF Signal Fail MJ SA FAILTOSW Failed to Switch MJ SA LOS Loss of Signal T-CVL Threshold Violation - CV Line T-ESL Threshold Violation - Errored seconds line WKSWPR Work
Alarm and Event Message Parameters Access Identifier Report Message Type Interface Type Default Notification Code * EXT48V-{A,B} REPT ALM ENV MN PWR-48 Power -48V Fail or Low FAN-{A,B} REPT ALM ENV MJ CLFAN Cooling Fan Fail FAN-A&FAN-B REPT ALM ENV MJ CLFAN Fan Faceplate Not Present POWER-5V{A,B} REPT ALM EQPT MN NSA PWR Power +5V Fail SECURITY REPT ALM SECU MJ NSA LOGBUFR90SECULOG TL1 Security Log 90% Full MJ NSA LOGBUFROVFLSECULOG TL1 Security Log Full HITEMP High T
Alarm and Event Message Parameters 48 Wide Bank 28 DS3 - Release 2.