User manual
Wide Bank 28 DS3 - Release 2.4 July 2004 2-3
Product Description
Overview
DS3 C-bit far-end alarm, statistics, and control
Ability to use TFTP to upload and download a configuration file to a file system on an IP host
(This function provides the ability to easily load multiple Wide Banks with the same
configuration).
Remote and local low-speed loopbacks with built-in PRBS for fault isolation on all active and
standby low-speed interfaces
Remote and local DS3 loopbacks with built-in PRBS test pattern generation for fault isolation
Transparent framing for DS1 or E1 channels
Individual DS1 support for AMI or B8ZS line coding
Individual E1 support for HDB3 line coding
Individual DS1 transmit line buildout (LBO) adjustments to 655 feet
DS3 line buildout (LBO) adjustments to 450 feet
DS1 transmit jitter attenuation and receive jitter tolerance
External critical and major/minor alarm relay contacts
DS3 clock source from DS3 network, internal Stratum 4E, or external coax input
Maintenance Service Option (MSO) that maintains T1 or E1 service on the spare low-speed
card while swapping failed electronics
Fan Faceplate Option (FFO), with dual independent fan design, allows direct metal-to-metal
stacking of Wide Banks in high-density applications where passive cooling is not sufficient.
(Direct stacking of Wide Bank products with other unapproved equipment is not
recommended and could lead to excessive heat buildup.)
Automatic monitoring for fan presence and fan failure, fault-tolerant fan redundancy, and in-
service hot swapping of FFO assembly in less than 30 seconds eliminates traditional fan
maintenance concerns