9-110 July 2004 Wide Bank 28 DS3 - Release 2.4
DS1-{01-28} REPT ALM EQPT MN NSA INT Internal Hardware Fault or Failure
REPT ALM T1 MN NSA BER-SD Signal Degrade
MJ SA BER-SF Signal Fail
MJ SA FAILTOSW Failed to Switch
MJ SA LOS Loss of Signal
REPT EVT T1 T-CVL Threshold Violation - CV Line
T-ESL Threshold Violation - Errored
seconds line
WKSWPR Working Unit Switched to Protect
Unit
WKSWBK Working Unit Switched Back to
Working
Not
Reported
ACTLPBK Loopback send code is Active
INHLPBK Loopdetect Off
INHSWPR Facility protection not enabled
INHSWWKG Equipment protection not enabled
LPBKEQPT Equipment loopback
LPBKLINE Line loopback
LPBKMETALLIC Metallic loopback
PROTNA Protection unit is not available
DS1-CARD-
{1-7}
REPT ALM EQPT MJ SA FAILTOSW Multiple MSO Card Removal
MJ SA IMPROPRMVL Improper Removal
DS1-CARD-
SPARE
REPT ALM EQPT MN NSA IMPROPRMVL Improper Removal
DS1-CARD-
MSO-{1-7}
REPT ALM EQPT MN NSA IMPROPRMVL Improper Removal
DS1-CARD-
MSO-SPARE
REPT ALM EQPT MN NSA IMPROPRMVL Improper Removal
Table 2-1 Alarm and Event Message Parameters (Continued)
Access
Identifier
Report
Message
Type
Interface
Type
Default
Notifi-
cation
Code
Service
or Con-
dition
Effect
Code
Condition Type Condition Description