User manual

Wide Bank 28 DS3 - Release 2.4 July 2004 9-109
TL1 Commands and Messages
TL1 Automatic Messages
DS3-{A,B} REPT ALM T3 MJ SA BER-SF Signal Fail
MN NSA BER-SD Signal Degrade
REPT EVT T3 WKSWPR Working Unit Switched to Protect
Unit
WKSWBK Working Unit Switched Back to
Working
REPT EVT T3 SC AISNAS Alarm Indication Signal - North
American Standard
RAI Remote Alarm Indication
REPT EVT T3 TC T-CVL Threshold Violation - CV Line
T-CVP-P Threshold Violation - CV Path p-
parity
T-ESL Threshold Violation - Errored
seconds line
T-ESP-P Threshold Violation - Errored
seconds path p-parity
T-LOSS-L Threshold Violation - Loss of signal
seconds line
T-SESL Threshold Violation - Severely
errored seconds line
T-SESCP-P Threshold Violation - Severely
errored seconds path
Not
Reported
ACTLPBK Loopback send code is Active
PROTNA Protection unit is not available
LPBKEQPT Equipment loopback
LPBKLINE Line loopback
LPBKPAYLOAD Payload loopback
INHAUTORSTEQPT Revertive Off
INHAUTORSTSYNC DS3 clockrevert Off
INHLPBK Loopdetect Off
INHSWPR Facility protection not enabled
INHSWWKG Equipment protection not enabled
Table 2-1 Alarm and Event Message Parameters (Continued)
Access
Identifier
Report
Message
Type
Interface
Type
Default
Notifi-
cation
Code
Service
or Con-
dition
Effect
Code
Condition Type Condition Description