User manual

TL1 Commands and Messages
TL1 Automatic Messages
9-102 July 2004 Wide Bank 28 DS3 - Release 2.4
aiddet Supplementary Access ID information used to identify location of
reported trouble:
MASTER – master Controller
SLAVE – slave Controller
almcde Alarm code identifies priority of action:
*C – Critical alarm
** – Major alarm
*^ – Minor alarm
A^ – Automatic message
If multiple alarms occur, the alarm code will be the highest severity.
atag Automatic message tag. A sequential value is assigned to each
message by the Wide Bank. Receiving a non-sequential value
indicates that some messages have been lost.
conddescr Condition Description provides a detailed description of the trouble.
condtype Condition Type. See Table 2-1 Alarm and Event Message
Parameters on
page 9-107 for values and descriptions.
dirn Direction of traffic:
•TRMT transmit
RCV – receive
NA – not applicable
HH:MM:SS Time (24 hour) in format Hours:Minutes:Seconds
locn Location:
NEND – near end
FEND – far end
modifier2 Identifies interface type:
EQPT – equipment
ENV – environment
T1 – DS1
T3 – DS3
SECU – security
ntfcncde Notification Code:
CR – Critical alarm
MJ – Major alarm
MN – Minor alarm
CL – condition cleared
ocrdat Occurrence Date: MM-DD
MM – month
DD – day
ocrtm Occurrence Time: HH-MM-SS
HH – hour
MM – minutes
SS – seconds
Field Description