User manual
Wide Bank 28 DS3 - Release 2.4 July 2004 9-91
TL1 Commands and Messages
TL1 Parameter Descriptions
DS3 Properties
Error Message: Invalid T3 Parameter or Value
tid 2001-08-04 13:18:00
M ctag DENY
INUP
/* Invalid Payload block. Invalid name value field. */
;
Environment Access Identifier (EnvAID)
Field Description and Possible Vales
CKTID Circuit Identification Parameter: ASCII string – up to 32 characters.
FMT DS3 digital signal format:
• CBIT – C-bit Parity format, M23 Framing format
• M23 – M23 Framing format
LBO Line Build Out (length):
• 1 – Short Line Length (< 50 feet)
• 2 – Long Line Length (>= 50 feet)
OMODE Output Mode:
• NORM – Normal Data
• AIS – Alarm Indication Signal
• QRSS – Quasi-random Signal, unframed
• Null value defaults to NORM.
• QRSU is not supported.
Field Description and Possible Values
ALL All of following. Null value defaults to ALL.
EXT48V-A External -48V Power Input to DS3 Controller A
EXT48V-A External -48V Power Input to DS3 Controller B
FAN-A Faceplate Fan A
FAN-B Faceplate Fan B
TEMP-A DS3 Controller A over temperature
TEMP-B DS3 Controller B over temperature