User manual

TL1 Commands and Messages
TL1 Parameter Descriptions
9-86 July 2004 Wide Bank 28 DS3 - Release 2.4
Additional Access Identifier Information <aiddet>
Because there can be two Controller cards, it may be necessary to specify whether the active or
standby Controller is being addressed.
Alarm Code <almcde>
This parameter identifies the severity of the autonomous message. Identifiers are:.
Alarm Message <almmsg>
The message is a detailed text description of the alarm. It is up to 40 characters long and enclosed
with a pair of escaped quotes.
ATAG Segment <atagseg>
This parameter specifies the list of alarm tag <atag> messages to be retrieved.
Automatic Message Tag <atag>
NOTE: For simplicity, examples and responses in this document will represent the
<atag> by the lower-case letters atag.
This field is represented by <atag>. This tag is used in sequence by the Wide Bank in automatic
messages. If an out-of-sequence value for this tag is received by the management application, it
means that some automatic messages may have been missed.
Command Mode <cmdmde>
This parameter indicates the command execution mode: NORM or FRCD. This is hard-coded to
FRCD in the Wide Bank, which means that existing parameter settings may be overridden in order
to execute the command.
Identifier Description
ACTIVE Active DS3 Controller
STANDBY Standby DS3 Controller
Identifier Description
*C Critical
** Major
*Minor
^A Automatic Message