User manual
TL1 Commands and Messages
TL1 Parameter Descriptions
9-84 July 2004 Wide Bank 28 DS3 - Release 2.4
Access Identifier <aid>
The Access Identifier determines which entity in the Wide Bank is addressed. The Access ID is
represented by <aid>.
NOTE: For commands specifying DS1 and E1 circuits, you can often use the single-
ampersand notation (&) to enter lists and the double-ampersand notation (&&) to specify
a range of DS1s or E1s. For example, to enter DS1 #1, #3, and #5, enter DS1-1&DS1-
3&DS1-5. To specify a range from DS1 #1 through #6, enter DS1-1&&DS1-6. The & and
&& notation can normally be used whenever the equivalent CLI command allows you to
enter a list or range.
Facility Type AID Description and Possible Values
E1 E1 Low Speed
Cards
E1-CARD-MSO-SPARE
E1-CARD-MSO-{1-7}
E1-CARD-SPARE
E1-CARD-{1-7}
E1 E1 Low Speed
Circuits
E1-SPARE-{1-4}
E1-{01-27}.
ENV Environment EXT48V-{A,B}
FAN-{A,B}
TEMP-{A,B}
EQPT Equipment POWER-5V-A
POWER-5V-B
DS1-SPARE-{1-4}
DS1-{01-28}
E1-SPARE-{1-4}
E1-{01-27}
DS1-CARD-MSO-SPARE
DS1-CARD-MSO-{1-7}
DS1-CARD-SPARE
DS1-CARD-{1-7}
E1-CARD-MSO-SPARE
E1-CARD-MSO-{1-7}
E1-CARD-SPARE
E1-CARD-{1-7}
DS3-A
DS3-B
T1 DS1 Low
Speed Cards
DS1-CARD-MSO-SPARE
DS1-CARD-MSO-{1-7}
DS1-CARD-SPARE
DS1-CARD-{1-7}
T1 DS1 Low
Speed Circuits
DS1-SPARE-{1-4}
DS1-{01-28}