User manual
TL1 Commands and Messages
TL1 Command List
9-76 July 2004 Wide Bank 28 DS3 - Release 2.4
Not Reported (NR) events do not produce any REPT messages. However, these
events are logged and can be retrieved by the RTRV-COND command (see RTRV-
COND-<AIDType> on page 9-59).
Category: Transport Surveillance Commands
Security: RW
Syntax: SET-ATTR-{T3|T1|E1|EQPT}:[<tid>]:[<aid>]:[<ctag>]::
<ntfcncde>,<condtype>,<locn>,<dirn>,<tmpr>;
Example: SET-ATTR-T1:tid::ctag::MN,LOS,,,;
Assign Minor alarm severity to T1 Loss of Signal.
Field Description
aid Access ID must be ALL or omitted
condtype Type of alarm or event condition.
Only the following conditions are valid:
• AISNAS – Alarm Indication Signal, North American
Standard
• BER-SF – Bit error rate signal failure
• BER-SD – Bit error rate signal degrade
• CONTEQPT – Control equipment failure
• FAILTOSW – Failure to switch
• IMPROPRMVL – Improper removal
• INT – Internal hardware failure
• INTERR – Internal error detected
• LOF – Loss of frame
• LOS – Loss of signal
• PWR – Power +5V failure
• RAI – Remote Alarm Indication
• SYNCPRI – Loss of designated clock
• TRMT – Transmitter failure
ctag Correlation Tag (optional)
dirn Direction – not supported in this release
locn Location – not supported in this release
ntfcncde Alarm severity notification code:
• CR – Critical, *C
• MJ – Major, **
• MN – Minor, *
• NA – Not Alarmed, A
• NR – Not Reported
tid
Target ID of network element (optional)
tmper Time period that these statistics were gathered – not supported
in this release