User manual
Wide Bank 28 DS3 - Release 2.4 July 2004 9-75
TL1 Commands and Messages
TL1 Command List
SET-ATTR-<AIDType>
Name: Set Attribute
Purpose: Assigns a severity to an alarm or event condition. All alarm and event conditions
(condtype) have default severities for notification conditions (ntfcnde) but most
severities can be changed by the user. The assigned severities apply to alarms and
events reported in the CLI and TL1 alarm messages and by the alarm LED indicators
and alarm output contacts on the unit.
NOTE: Notification codes can only be changed through the TL1 interface, except for the
standby Controller self-test failure and communications failure (see ALARMS STANDBY
on page 8-11).
This command does not apply to environment (ENV) conditions.
Transient Conditions (TC) can be assigned to Not Alarmed (NA) and Not Reported
(NR) severities.
Condition severities are retrieved with the command RTRV-ATTR-<AIDType> on
page 9-56.
Critical (CR), Major (MJ), and Minor (MN) alarms are reported by REPT ALM
messages (see
TL1 Automatic Messages on page 9-101).
Not Alarmed (NA) events are reported by REPT EVT messages (see TL1 Automatic
Messages on
page 9-101).
reptinvl Reporting Interval (optional) specifies how often reports are to be
generated and sent:
• 15-MIN – (default)
•1-HR
• 1-DAY
reptstatm Reporting Start Time (optional) specifies the time when the reports
should start being generated. All selections will start reports at end of
current reporting interval
• null – (default)
•0-0
•00-00
tid
Target ID of network element (optional)
tmper Time Period (optional):
•15-MIN
•1-HR
• 1-DAY}
Note: tmper must be equal to reptinvl or omitted.
Field Description