User manual
TL1 Commands and Messages
TL1 Command List
9-60 July 2004 Wide Bank 28 DS3 - Release 2.4
Example: RTRV-COND-T3:tid::ctag;
Receive severities for all T3 alarms, as in the following response:
Response:
tid 2001-08-04 05:05:51
M ctag COMPLD
"DS3-A,T3:LOS,SA,01-01,04-42-21,NEND,RCV,,\"Loss of Signal\""
"DS3-A,T3:INHLPBK,NSA,,,,,,\"Loopdetect Inhibited\""
"DS3-A,T3:INHSWPR,NSA,,,,,,\"DS3 Facility Protection Not Enabled\""
"DS3-A,T3:PROTNA,NSA,,,,,,\"Protection Unit not Available\""
;
Field Description
aid Access ID. See Access Identifier <aid> on page 9-84
ntfcncde Severity or class of alarm, event or condition.
See Notification Code <ntfncde> on
page 9-96.
condtype Type of alarm or condition.
See
Condition Type <condtype> on page 9-87
srveff Service Effect.
See
Service Effect of Alarm or Condition <srveff> on
page 9-98
ocrdat Date when the event was detected (format: mm-dd)
ocrtm Time when the event was detected (format: hh-mm-ss)
locn Location.
See
Location of Alarm or Condition <locn> on page 9-92
dirn Direction.
See
Direction of Alarm or Condition <dirn> on page 9-89
tmper Time period:
• 15-MIN – 15 minutes
• 1-HR – 1 hour
• 1-DAY – 1 day
conddescr Detailed Description of Alarm condition. A maximum of 64
characters enclosed in escaped quotes (\") .