User manual

Wide Bank 28 DS3 - Release 2.4 July 2004 9-57
TL1 Commands and Messages
TL1 Command List
Field Description
aid Access ID must be ALL or omitted
condtype Type of alarm or event condition.
Only the following conditions are valid:
ACTLPBK – Loopback send code is Active
AISNAS – Alarm Indication Signal, North American Standard
BER-SF – Bit error rate signal failure
BER-SD – Bit error rate signal degrade
CONTEQPT – Control equipment failure
FAILTOSW – Failure to switch
IMPROPRMVL – Improper removal
INHAUTORSTEQPT – Revertive Off
INHAUTORSTSYNC – DS3 clockrevert Off
INHLPBK – Loopdetect Off
INHSWPR – Facility protection not enabled
INHSWWKG – Equipment protection not enabled
INT – Internal hardware failure
INTERR – Internal error detected
LOF – Loss of frame
LOS – Loss of signal
LPBKEQPT – Equipment loopback
LPBKLINE – Line loopback
LPBKMETALLIC – Metallic loopback
LPBKPAYLOAD – Payload loopback
NORMAL – Normal is used only for REPT EVT “clear” condition,
with clarification in the description field to indicate which
condition has cleared.
PROTNA – Protection unit is not available
PWR – Power +5V failure
RAI – Remote Alarm Indication
SYNCPRI – Loss of designated clock
TRMT – Transmitter failure
T-CVL – Threshold Violation - CV Line
T-CVP-P – Threshold Violation - CV Path p-parity
T-ESL – Threshold Violation - Errored seconds line
T-ESP-P – Threshold Violation - Errored seconds path p-parity
T-LOSS-L – Threshold Violation - Loss of signal seconds line
T-SESL – Threshold Violation - Severely errored seconds line
T-SESCP-P – Threshold Violation - Severely errored seconds path
WKSWPR – Working Unit Switched to Protect Unit
WKSWBK – Working Unit Switched Back to Working
ctag Correlation Tag (optional)
dirn Direction
RCV – receive
TX – transmit