User manual

TL1 Commands and Messages
TL1 Command List
9-54 July 2004 Wide Bank 28 DS3 - Release 2.4
Response: tid 2001-08-04 11:51:58
M ctag CMPLD
"FAN-A & FAN-B:MJ,CLFAN,01-01,01-00-44,\"Fan Faceplate Not Present\""
"EXT48V-A:MN,PWR-48,01-01,01-00-49,\"Power -48V Fail or Low\""
"EXT48V-B:MN,PWR-48,01-01,01-00-49,\"Power -48V Fail or Low\""
"TEMP-A:MN,HITEMP,01-01,01-00-51,\"High Temp\""
"TEMP-B:MN,HITEMP,01-01,01-00-51,\"High Temp\""
;
RTRV-AO
Name: Retrieve Automatic Output
Purpose: Retrieves queued automatic messages or specific automatic messages when an out-of-
sequence automatc tag <atag> is received.
Category: Memory Administration Commands
Security: R
Syntax: RTRV-AO:[<tid>]::[<ctag>]:::
[ATAGSEQ=<atagseq>],[MSGTYPE=<msgtype>];
Example: RTRV-AO:tid::ctag:::
ATAGSEQ=100&&110,MSGTYPE=ALM;
Retrieve Alarm Messages with an <atag> from 100 to 110.
Field Description
ATAGSEQ= Retrieve messages with a specific <atag> (see Automatic Message
Tag <atag> on
page 9-86). The value can be replaced by an integer
or integers. Multiple or a range of values can be specified by using
the & or && respectively. For example, ATAGSEQ=301&&320 will
cause the messages with an <atag> from 301 to 320 to be retrieved.
ctag Correlation Tag (optional)
MSGTYPE= Retrieve messages of a specific type: ALM, EVT, ALL. (see Message
Type <msgtype> on
page 9-94). For example, MSGTYPE=ALM
will retrieve all the messages reported by the “REPT ALM” message.
See TL1 Automatic Messages on
page 9-101.
tid
Target ID of network element (optional)