User manual

Wide Bank 28 DS3 - Release 2.4 July 2004 9-49
TL1 Commands and Messages
TL1 Command List
Example: RTRV-T1:tid:DS1-2:ctag;
This command retrieves the configuration for DS1 #2.
Response: tid 2001-08-04 11:51:58
M ctag COMPLD
"DS1-02::AISF=Y,CMDMDE=FRCD,DLCID=DS1 2,
FLMDE=BOTH,FMT=UNFR,IDLE=AIS,LBO=1,LINECDE=B8ZS,
OMODE=NORM,RVRTFLAG=UNLCKD:IS-EQ,NALMNR"
;
Example: RTRV-E1:tid:E1-1:ctag;
This command retrieves the configuration for E1 #1.
Response: tid 2001-08-04 11:47:18
M ctag COMPLD
"E1-01::AISF=Y,CMDMDE=FRCD,DLCID=E1 1,
FLMDE=BOTH,FMT=UNFR,IDLE=AIS,LINECDE=HDB3,
OMODE=NORM,RVRTFLAG=UNLCKD:IS-EQ,"
;
Field Description
AISF Indicates whether failed signal from upstream should be replaced by
AIS. This is hard-coded to Y in the Wide Bank.
CMDMDE Indicates command execution mode. This is hard-coded to FRCD in
the Wide Bank. This means that existing parameter settings may be
overridden in order to execute the command.
DLCID The DS1 or E1 digital loop carrier system identifier. This is a string
of ASCII characters and has a maximum length of 32 characters.
FLMDE Indicates the fault locate mode. This is hard-coded to BOTH in the
Wide Bank.
FMT Indicates DS1 digital signal format. This is hard-coded to UNFR in
the Wide Bank.
IDLE Indicates the signal inserted for idle DS1. This is hard-coded to AIS
in the Wide Bank.
LBO Indicates the line buildout setting. Values are 1-6. Line Build Out
(length) applies to T1 only (E1 has no LBO).
1 – DSX (0-110 ft.)
2 – DSX (110-220 ft.)
3 – DSX (220-330 ft.)
4 – DSX (330-440 ft.)
5 – DSX (440-550 ft.)
6 – DSX (550-660 ft.)