User manual

Wide Bank 28 DS3 - Release 2.4 July 2004 9-37
TL1 Commands and Messages
TL1 Command List
INH-MSG-<AIDType>
Name: Inhibit Message
Purpose: Used by the administrator to disable the transmission of automatic messages and
alarms. To allow messages, see ALW-MSG-<AIDType> on page 9-20. Notification
codes (alarm severities) for many conditions can be altered through the TL1 interface,
see SET-ATTR-<AIDType> on page 9-75.
Category: Transport Surveillance Commands
Security: RWA
Syntax: INH-MSG-{T3|T1|E1|EQPT|ALL}:[<tid>]:
[<aid>]:[<ctag>]::[<ntfcncde>],[<condtype>];
Example: INH-MSG-T1:tid:DS1-1:ctag::,;
Inhibits messages for DS1 #1.
Example: INH-MSG-T1:tid::ctag::MJ,;
Inhibits major DS1 messages.
Example: INH-MSG-T1:tid::ctag::,LOS;
Inhibits DS1 LOS messages.
Field Description
aid Access ID. Values depend on facility type: T1, E1, EQPT, T3, or
ALL. See Access Identifier <aid> on
page 9-84
condtype Type of alarm or condition.
•See Condition Type <condtype> on
page 9-87
ctag Correlation Tag (optional)
ntfcncde Severity or class of alarm, event or condition. Values are:
CR – Critical Alarm
MJ – Major Alarm
MN – Minor Alarm
CL – Condition Cleared
NA – Not Alarmed
•NR Not Reported