User manual
Wide Bank 28 DS3 - Release 2.4 July 2004 9-33
TL1 Commands and Messages
TL1 Command List
ENT-<LSType>
Name: Enter {T1|E1}
Purpose: Creates equipment DS1 or E1 parameters and puts the facility in service. To retrieve
the configuration, see RTRV-<FacilityType> on page 9-47.
Category: Memory Administration Commands
Security: RW
Syntax: ENT-{T1|E1}:[<tid>]:<aid>:[<ctag>]:::
[DLCID=<dlcid>],[LBO=<lbo>],[LINECDE=<linecde>],
[OMODE=<omode>];
Example: ENT-T1:tid:DS1-8:ctag:::LINECDE=AMI;
Create DS1 #8 with Line Code set to AMI.
Field Description
aid Access ID:
• For T1 modifier, values are DS1-1 to DS1-28
• For E1 modifier, values are E1-1 to E1-27
ctag Correlation Tag (optional)
tid
Target ID of network element (optional)
DLCID= T1/E1 Circuit ID: ASCII string of up to 32 characters
LBO= Line Build Out (length) applies to T1 only (E1 has no LBO).
Values are 1 to 6.
• 1 – DSX (0'-110')
• 2 – DSX (110'-220')
• 3 – DSX (220'-330')
• 4 – DSX (330'-440')
• 5 – DSX (440'-550')
• 6 – DSX (550'-660')
LINECDE= Line Code: {AMI|B8ZS}
• AMI – Alternate Mark Inversion
• B8ZS – Bipolar with 8-Zero Substitution
This parameter is only used with the T1 modifier.
(E1 is hard coded to HDB3.)
OMODE= Output Mode: {NORM|AIS}
• NORM – Normal Data
• AIS – Alarm Indication Signal
• Null value defaults to NORM
Note: QRSU is not supported.