User manual
Wide Bank 28 DS3 - Release 2.4 July 2004 9-29
TL1 Commands and Messages
TL1 Command List
ED-<AIDType>
Name: Edit {T3|T1|E1}
Purpose: Edits configuration of AIDs. To retrieve the configuration, see RTRV-<FacilityType>
on page 9-47.
Category: Memory Administration Commands
Security: RW
Syntax: ED-T3:[<tid>]:ALL:[<ctag>]:::
[CKTID=<cktid>],[FMT=<fmt>],[LBO=<lbo>],[OMODE=<omode>],
[TMG=<tmg>],TMGLOCK=<tmglock>];
Syntax: ED-T1:[<tid>]:<aid>:[<ctag>]:::
[DLCID=<dlcid>],[LBO=<lbo>],[LINECDE=<linecde>],
[OMODE=<omode>];
Syntax: ED-E1:[<tid>]:<aid>:[<ctag>]:::
[DLCID=<dlcid>],[OMODE=<omode>];
Syntax: ;
Field Description
aid Access ID is optional and if omitted will default to ALL:
• ALL specifies all circuits covered by the modifier
• For T3 modifier, values are DS3-A and DS3-B
• For T1 and E1 modifiers, values can be ALL, a range, a list, or one
circuit
• For T1 modifier, values are DS1-1 to DS1-28
• For E1 modifier, values are E1-1 to E1-27,
except E1-4, E1-8, E1-12, and so on, are not allowed
ctag Correlation Tag (optional)
tid
Target ID of network element (optional)
cktid T3 Circuit ID: ASCII string of up to 32 characters
dlcid T1/E1 Circuit ID: ASCII string of up to 32 characters
fmt TS/DS3 digital signal format:
This parameter is only used with the T3 modifier.
• CBIT – C-bit Parity format
• M23 – M23 Framing format