User manual
Wide Bank 28 DS3 - Release 2.4 July 2004 9-15
TL1 Commands and Messages
TL1 Setup and Configuration
Retrieving Alarms
The retrieve alarm all command retrieves all outstanding alarms from the Wide Bank’s alarm log
without filtering for alarm specifics.
RTRV-ALM-ALL:MULTIPLEXER-1::23;
NOTE: Notification codes (alarm severities) for many conditions can be altered through
the TL1 interface. See SET-ATTR-<AIDType> on page 9-75.
Response if No Alarms are Present
MULTIPLEXER-1 01-12-07 01:41:20
M 23 COMPLD
;
Response if Alarms are Present
The following example represents the case where one alarm of each type is present (for brevity,
not all alarms are shown):
MULTIPLEXER-1 01-12-07 01:41:20
M 23 COMPLD
"DS3-A,T3:CR,LOS,SA,01-01,01-41-19,NEND,RCV:\"Loss of Signal\",ACTIVE"
"DS3-B,T3:CR,LOS,SA,01-01,15-39-53,NEND,RCV:\"Loss of Signal\",ACTIVE"
"DS3-A,T3:CR,LOF,SA,01-01,19-31-32,NEND,RCV:\"Loss of Frame\",ACTIVE"
"DS3-B,T3:CR,LOF,SA,01-01,19-32-35,NEND,RCV:\"Loss of Frame\",ACTIVE"
"DS1-17,T1:MJ,INT,SA,01-01,17-29-48,,:\"Internal Hardware Fault or Failure\","
"DS1-2,T1:MJ,LOS,SA,01-01,01-05-57,NEND,RCV:\"Loss of Signal\","
;
Retrieve Header Command
Use the retrieve-header command to test if the Wide Bank is operating. A normal response
indicates that the Wide Bank is alive.
RTRV-HDR:MULTIPLEXER-1::34;
The following message represents a normal response:
MULTIPLEXER-1 01-12-07 01:41:20
M 34 COMPLD
;