User manual

Wide Bank 28 DS3 - Release 2.4 July 2004 8-11
CLI Commands and Messages
CLI Command List
ACO
Name: Alarm Cut Off
Purpose: Activates the Alarm Cut Off, which deactivates the alarm relay contacts to suppress the
alarm.
Security: rw and above
Syntax: aco
ALARMS
Name: Alarms
Purpose: Display the currently active alarms.
Security: ro and above
Syntax: alarms
Example: alarms
Sev Active Alarm
--- ------------
CR DS3 A Loss Of Signal
Syntax: aco
ALARMS STANDBY
Name: Alarms Standby
Purpose: Set the severity of failure conditions for the standby DS3 Controller when logging and
reporting alarms (REPT ALM) and events (REPT EVT). The severity of many other
failure conditions can be set by the TL1 command SET-ATTR-<AIDType> on
page 9-75.
The “standby self-test” is only run when the standby Controller is initialized. Other CLI
commands (test all, test ds3) and TL1 commands (dgn-t3-all, dgn-all) only run a self-
test on the active Controller card.
The “other controller bad” condition occurs if the active Controller loses
communications with the standby Controller. Both conditions cause a CONTEQPT,
“Control Equipment Failure”, STANDBY.
Note: The Wide Bank restricts standby Controller condition severities to values that
are equal to or less than the corresponding active Controller settings. You can still set
a standby condition severity to a greater value but the actual reported value will be
restricted by the active Controller setting, as shown in the following examples.