User manual

Diagnostics & Troubleshooting
Testing DS3 Interfaces
7-34 July 2004 Wide Bank 28 DS3 - Release 2.4
ds3 facilityid "DS3 Path"
ds3 frameid "Frame"
ds3 framing cbit
ds3 gennumber "DS3 Test Generator"
ds3 length short
ds3 line off
ds3 locationid "DS3 Loc."
ds3 loopdetect off
ds3 payload off
ds3 portnumber "DS3 Idle Port"
ds3 send off
ds3 threshold off
ds3 unit "000000"
Performance Thresholds: 15 min. 1 hour 1 day
-------- -------- --------
coding violations - line: 0 0 0
errored seconds - line: 0 0 0
coding viols-path p-bit: 0 0 0
err seconds - path p-bit: 0 0 0
loss of signal secs - line: 0 0 0
sev err seconds - line: 0 0 0
sev err sec - path cp-bit: 0 0 0
2. Configure the test set for C-bit Parity framing, and verify that the test set frames up.
DS3 Tests with Line Timing
1. Configure the clock source to use line timing (provided by the test set).
(A:Active)> ds3 clock line
2. Repeat preceding DS3 Test with M23 Framing and DS3 Test with C-bit Framing for line clock
source.
3. Configure clock source to internal for the following tests.
(A:Active)> ds3 clock int