User manual

Electrical Installation and Cabling
Management Cables
5-10 July 2004 Wide Bank 28 DS3 - Release 2.4
Management Cables
CLI RS-232 Management Cable ... 5-10
TL1 RS-232 Port Cable ... 5-11
Ethernet Management Port ... 5-11
External Alarm Wiring ... 5-12
CLI RS-232 Management Cable
The RS-232 management port can be connected to an RS-232 terminal or a PC running terminal
emulation software such as Hyperterm. Set the port for 9600 baud, 8 data bits, 1 stop bit, no parity,
and no flow control.
Figure 5-7 Connecting the Management Cables
The RS-232 CLI management cable must be a shielded RS-232 cable
with a male DB9 connector. Connect management cable to RS-232 port
on the Wide Bank. For compliance with FCC standards, install a ferrite
RF suppressor as shown at right. Note that the cable is looped 360º
through the suppressor, then the suppressor is closed and latched.
Figure 5-8 Installing the RS-232 Port Cable and Ferrite RF Suppressor
9-Pin RS-232 Pinout
2 RD
3 TD
5 GND
Receive Data
Transmit Data
Signal Ground
TL1 PortEthernet Port
RS-232 Port
RS-232 (COM) Port