Owner's Manual

18
Remove the battery pack from the tool before carrying out any adjustment, servicing or maintenance.
Your tool requires no additional lubrication or maintenance.
There are no user serviceable parts in your power tool. Never use water or chemical cleaners to clean your power tool.
Wipe clean with a dry cloth. Always store your power tool in a dry place. Keep the motor ventilation slots clean. Keep all
working controls free of dust. Occasionally you may see sparks through the ventilation slots. This is normal and will not
damage your power tool.
Remove the battery pack from the tool if the tool is not used for more than 24 hours.
For Battery tools
The ambient temperature range for the use and storage of tool and battery is 0°C-45°C.
The recommended ambient temperature range for the charging system during charging is 0°C-40°C.
Fault Cause Remedy
The tool does not start up after
switch on.
Battery depleted. Charge the battery.
Defective on/off switch. Contact the service centre.
Defective motor. Contact the service centre.
The tool suddenly stops during
operation.
Overload Relieve the load on the machine immediately
and allow cooling for approx. 30 seconds by
running the machine on no-load.
Battery temperature too high
Low battery capacity Charge the battery pack.
MAINTENANCE
TROUBLESHOOTING
Waste electrical products must not be disposed of with household waste. Please recycle where facilities exist.
Check with your local authorities or retailer for recycling advice.
ENVIRONMENTAL PROTECTION