SDS
SAFETY DATA SHEET
R134A
Page 4 / 13 
 Version 2.6 
Revision Date 06/06/2014  Print Date 02/14/2016 
In case of fire hazardous  decomposition products may 
be produced such as: 
Hydrogen  halides 
Hydrogen  fluoride 
Carbon  monoxide 
Carbon  dioxide (CO2) 
Carbonyl  halides 
Special protective 
equipment for firefighters 
:  In the event  of fire and/or explosion do not breathe  fumes. 
Wear self-contained  breathing apparatus  and protective 
suit. No unprotected  exposed skin areas. 
SECTION 6. ACCIDENTAL  RELEASE MEASURES 
Personal precautions  :  Immediately  evacuate  personnel to safe areas. 
Keep people  away from  and upwind  of spill/leak. 
Wear personal protective  equipment.   Unprotected 
persons must be kept away. 
Remove all sources  of ignition. 
Avoid  skin contact with leaking liquid (danger  of frostbite). 
Ventilate the area. 
After release, disperses into the air. 
Vapours are heavier  than air and can cause suffocation 
by reducing  oxygen available  for breathing. 
Avoid  accumulation of vapours in low areas. 
Unprotected  personnel should not return until air has been 
tested and determined  safe. 
Ensure that the oxygen content is >= 19.5%. 
Environmental  precautions  :  Prevent  further leakage or spillage if safe to do so. 
The  product evapourates  readily. 
Methods for cleaning  up  :  Ventilate the area. 
SECTION 7. HANDLING AND STORAGE 
Handling 
Handling  :  Handle  with care. 
Avoid  inhalation  of vapour  or mist. 