Instructions/Assembly Guide

WINDOW KIT INSTALLATION
4. Insert the other end of exhaust hose assembly with the exhaust connector onto the window panel kit and turn
counterclockwise to secure.
5. Plug the power cord into the wall outlet and press the “Reset” button.
6. Please allow 20” of space around the unit for proper air circulation.
7. When removing the portable air conditioner for storage, the window panel may be left in place. Simply place the included
cover to cover the hole on the window panel.
FILTER INSTALLATION AND DRAINAGE
WARNING: NEVER OPERATE THE AIR CONDITIONER WITHOUT THE AIR
FILTER
Your Whynter portable air conditioner is equipped with a washable filter.
This washable filter removes large particles such as dust, pet hair and
dander.
WATER DRAINAGE
The dehumidifying capacity of this unit is 87 pints per day. The patented
self-evaporating function of the ARC-115WG unit fully exhausts all
condensation automatically in most en-vironments when humidity is less
than 70%. Areas with more than 70% humidity, the self-evaporating
function can still exhaust about 98% of the moisture and the remaining
2% of moisture will be collected in the water tank of the air conditioner.
When the water reservoir reaches its maximum level, the water full
indicator light will illuminate and all operation modes will be
disabled temporarily while the fan continuously runs. The water full
indicator light will disappear when the water is completely drained.
Continuous gravity drainage (Fig. A) - optional
Remove the drain cover and soft rubber stopper from the upper drain
port. Install the drain hose (sold separately) through the driven cover.
Thread the drain cover onto the drain port. Place the open end of the
drain hose downward to an area appropriate for draining.
Manual drainage (Fig. B)
Carefully move the unit to a drain location or position a flat container,
dish or optional drain bucket accessory (sold separately) under the drain
area of the lower drain port. Remove the bottom drain plug and let the
water drain. Replace the drain plug and plug in to resume operation.
Drain hose
Drain cover
Soft rubber stopper
Fig. A
Fig. B
8