Instructions/Assembly Guide

The unit has worked for a long me, but
the room is not cold enough
Windows or doors are open
There are too many people in the
room
There is direct sunshine into the room
The room is a kitchen or with many
heat producing appliances
There is a server in the room
The room is too large
Close all windows and doors
You may need addional cooling or
another air condioner.
Close curtains or blinds and try to
minimize the amount of direct sun-
light into the room.
You may need addional cooling or
another air condioner.
The unit is very noisy
The unit is not level
The surface underneath the unit is
uneven
Low power voltage
Make sure the unit is on hard, level
and stable surface.
Move the unit to a locaon with a
level and hard oor.
Make sure the wall outlet and support
the required power consumpon of
the air condioner and do not use an
extension cord.
The unit leaks water
The unit is lted or not leveled
The water tank is full
Make use the unit is leveled
Drain water from the drain plug at the
back of the air condioner
Fan speed cannot be changed
Fan speed dierences are not very
noceable
The fan speed dierence is not very
noceable when the compressor is on.
Try seng the unit to Fan only mode,
you should be able to hear the dier-
ence between high and low fan speed
sengs.
The air coming out of the unit is
not very cold, or the airow
volume is weak
The lters are dirty or obstructed
The air intake or exhaust is obstructed
The unit is set in DRY or FAN mode
The unit is set to low fan speed
Clean the air lters
Make sure there is at least 20" of
clearance from the air intake. Make
the length of the exhaust hose is as
short as possible
Set the unit to the cooling mode
Set the unit to a higher fan speed
The unit turns on but the compressor
does not turn on (the fan runs but the
unit is not cooling)
The room temperature is outside of
the operational tolerances of the unit
The Cooling mode is not on
The compressor has not turned on yet
because of its time delay
The set temperature is too high
The internal water reservoir is full
This unit is designed to work in ambi-
ent temperatures of 61°F to 95°F.
Press the MODE button until the
COOL light is shown on the display.
Give the compressor 3 minutes to
turn on after the Cooling mode has
been selected.
Set the air conditioner to a lower tem-
perature.
It is recommended to set the temper-
ature to at least 5°F of the ambient
temperature.
Either manually drain the water by
removing the drain plug or allow the
unit to exhaust the water itself by run-
ning the fan only mode. Then cooling
will resume.
Possible loose internal connection.
Please contact Whynter for service.
PROBLEM POSSIBLE CAUSES SOLUTIONS
14