Specification
14
OPERATION INSTRUCTIONS 
TIMER (DELAYED SWITCH ON / OFF) FUNCTION 
This function mode enables a delayed switch ON or delayed switch OFF of the air conditioner. The time (hours) de-
lay can be set, enabled and disabled.
SETTING SWITCH OFF TIMER 
With the air conditioner operating in any function mode, press the TIMER button. The TIMER OFF light will come on. 
Then set the desired time delay OFF hours by pressing the UP and DOW N buttons. The time increments are at 0.5 
hour to up to 10 hours, followed by 1 hour increment up to 24 hours. When the delay time set has elapsed, the air 
conditioner switches off. To cancel the delayed switch off function, turn off the air conditioner or adjust the time set-
ting to 0.0. 
SETTING DELAYED SWITCH ON TIMER 
With the air conditioner is off, press the TIMER button. The TIMER ON light will come on. Then set the desired time 
delay ON hours by pressing the UP and DOW N buttons. The time increments are at 0.5 hour to up to 10 hours, fol-
lowed by 1 hour increment up to 24 hours. When the delay time set has elapsed, the air conditioner switches on. To 
cancel the delayed switch on function, turn on the air conditioner or adjust the time setting to 0.0. 
SLEEP MODE 
In this mode, the air conditioner gradually increases the set temperature in cooling mode, decreases the noise level 
and conserves energy. In Sleep and cooling mode, the set temperature is increased by 1°C/ 2°F in the first 30 
minutes. The temperature will then increase by another 1°C/ 2°F after an additional 30 minutes. This new tempera-
ture will remain the same for 7 hours. To activate this function mode, press the SLEEP button until the SLEEP  
indicator light comes on. 
AUTO RESTART 
In the event of a power outage, the air conditioner restarts at the previously set function mode and settings when 
power is restored.  
CONTROLLING THE AIR FLOW DIRECTION 
The louvers can be controlled in a fixed direction. To set the louvers in a fixed angle or direction, manually adjust the 
louvers to you desired angle.  
NOISE LEVEL 
Portable air conditioners may make sounds that are not familiar to you. The sounds listed below are normal. Noise 
reflecting off hard surfaces such as a floor or wall can make the sounds seem louder than they actually are. 
 The compressor may make a pulsating or high-pitched sound
 Water running from the evaporator to the water tank may make a splashing sound
 Refrigerant flowing may make a gurgling sound
 Fan sound may come from front and back air vents
COMPRESSOR LOCK OUT 
This portable air conditioner is optimized to operate in an ambient temperature of 64°F – 90°F. The compressor cir-
cuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly. This prevents over-heating of 
the compressor and possible circuit breaker tripping.  
SHORTCUT FUNCTION 
Push this button when remote controller is on, the system will automatically revert back to the previous settings in-
cluding operating mode, setting temperature, fan speed level and sleep feature (if activated). If shortcut button is 
pushed for more than 2 seconds, the system will automatically store the current operation settings including operat-
ing mode, setting temperature, fan speed level and sleep feature (if activated ). 