Product Specifications

WARRANTY: Five year warranty period. Contact Morningstar or your authorized distributor for complete terms.
Revision: 11/2016.EN
Control no. MS-001897
Copyright 2016
www.morningstarcorp.com
TECHNICAL SPECIFICATIONS
Options
TriStar 600V Meter (TS-M-2-600V)
TriStar Remote Meter (TS-RM-2)
Meter Hub (HUB-1)
Relay Driver (RD-1)
600V Ground Fault Protection Device (GFPD-600V)
Certifications
CE, RoHS, NEC Compliant
ETL Listed: UL-1741 and Canadian CSA C22.2 No. 107.1.01
FCC Class B Part 15 Compliant
Communication
Ports Ethernet, EIA-485, RS-232, MeterBus
Supported Protocols
MeterBus, MODBUS RTU, MODBUS TCP/
IP, HTTP, SNMP v2, SMTP
Mechanical
Dimensions
Standard Version 39.2 x 22.1 x 14.9 cm / 15.4 x 8.7 x 5.9 in
DB & TR Version 54.2 x 22.1 x 14.9 cm / 21.4 x 8.7 x 5.9 in
Unit Weight
Standard Version 9.0 kg / 19.8 lbs
DB & TR Version 12.8 kg / 28.1 lbs
Maximum Wire Size
Power Terminals 2.5 mm
2
- 35 mm
2
/ 14 AWG - 2 AWG
RTS/Sense Terminals
0.25 mm
2
- 1.0 mm
2
/ 24 AWG - 16 AWG
Conduit Knockouts M20; 0.50, 1.00, 1.25 inches
Enclosure Rating Type 1 (indoor and vented), IP20
Battery Charging
Charging Stages MPPT, absorption, float, equalize
Temperature Compensation
Coefficient -5mV/°C/cell (25° ref)
Range -30 °C to +80 °C / -22 °F to +176 °F
Set points Absorption, Float, Equalize, HVD
Note: Remote Temperature Sensor is included.
Environmental
Ambient Temperature -40 °C to +45 °C
Storage Temperature -55 °C to +85 °C
Humidity 100% non-condensing
Tropicalization Epoxy encapsulation, conformal
coating, marine-rated terminals
Electronic Protections
Input Overload, high voltage
Battery High voltage, battery sense disconnected,
remote temperature sense disconnected
General Operation High temperature, reverse current at night,
lightning and transient surges
Electrical
Peak Efficiency 97.9%
Maximum Battery Current 60A
Maximum Input Operating Current 15A (self limiting)
Maximum Solar Open Circuit Voltage 600V
Nominal Maximum Operating Power**** 3200Wp, 48 Volt
Nominal System Voltage 48 Vdc
custom programmable to 24V, 36V and 60V
Battery Operating Voltage Range 16-72 Vdc
PV Input Operating Voltage Range 100V to Voc = 525V
Wind/Hydro Input Operating
Voltage Range
Battery Voltage to 500V
Self-Consumption 1.75 - 2.50 W
Transient Surge Protection 4500 Watts/port
Four Versions:
TS-MPPT-60-600V-48 Standard
TS-MPPT-60-600V-48-DB With Disconnect Box (600V; 25A 1-Pole disconnect switch)
TS-MPPT-60-600V-48-DB-TR* With DC Transfer Switch (600V; 30A double pole; double throw DC Transfer Switch)
TS-MPPT-60-600V-48-DB-TR-GFPD** Pre-wired with Ground Fault Protection Device
All non-standard versions include a 1-Pole; 63A PV battery breaker*** and pre-wired PV/Battery busbars
TR versions also include a pre-wired String Inverter busbar
* Can be used as a 2-pole version of the Disconnect Box.
** See GFPD-600V datasheet for additional specifications.
*** Can be replaced with 2-pole battery breaker.
**** Input power can exceed Nominal Maximum Operating Power, but controller will limit and provide its rated
continuous maximum output current into batteries. This will not harm the controller.