Installation Guide
15 TriStar MPPT-600V-TR Operator's Manual
14
Getting Started
2.4 Features
The features of the TS-MPPT-600V-TR-GFPD model are shown below in Figure 2-1. An
explanation of each feature follows.
Figure 2-1. TS-MPPT-600V-TR-GFPD Features
TS-MPPT-60-600V-48-DB-TR Box
1 - Heatsink
Aluminum heatsink to dissipate controller heat (the TS-MPPT-600V-TR is 100% passively cooled
for reliability)
2 - Battery Negative Power Terminal
Power connection for (-) battery cable termination
3 - Battery Positive Power Terminal (red)
Power connection for (+) battery cable termination
4 - Settings Switches
Eight (8) settings switches to conīægure operation of the TS-MPPT-600V-TR-DB
5 - MeterBus
TM
Port
RJ-11 socket for Morningstar MeterBus
TM
network connections
6 - Ethernet Port
RJ-45 socket for LAN/internet connections
7 - Serial RS-232 Port
9-pin serial connector (female)
8 - EIA-485 Port
Four (4) position screw terminal for EIA-485 bus connections
9 - Battery Breaker [(63A rating), (pre-wired)]
Battery (+) disconnect point
10 - Battery Terminal Blocks
(+) and (-) battery terminal connection points
11. - Grounding Terminal Block
A chassis terminal for equipment grounding
12 - Solar Terminal Blocks
(+) and (-) solar terminal connection points
13 - Connections Points out to Grid-Tie Inverter Solar Input
14 - Transfer Switch
Controls grid-tie and battery charging modes
15 - LED Indicators
Show battery state-of-charge (SOC) and controller fault conditions
16 - Remote Temperature Sensor Terminals
Connection point for a Morningstar RTS to remotely monitor battery temperature
17. Push-button Switch
Manually reset from an error or fault. Start/stop a manual equalization.
18 - Battery Voltage Sense Terminals
Terminals for battery voltage input provide accurate battery voltage measurement
2
3
4
5
6
7
8
10
20
19
9
18
17
16
15
11
14
13
12
21
22
23
24
25
29
28
27
26
1