Installation Guide
65 TriStar MPPT-600V-TR Operator's Manual
64
Networking and Communication
Custom Settings
The TriStar MPPT Setup Wizard in MSView
TM
provides an interface to adjust all operating param-
eters. Morningstar’s MSView
TM
PC software can connect to any TS-MPPT-600V-TR on the
Ethernet network or through a RS-232 serial connection. Refer to the help documentation
included with MSView
TM
for more information.
Email & SMS Alerts
The email and SMS alerts feature sends notication to an email address or mobile phone if one
of the following occurs:
• TS-MPPT-600V-TR self diagnostics fault condition
• TS-MPPT-600V-TR self diagnostics alarm condition
• User-dened event (e.g. battery voltage is less than 46 Volts)
Up to four email and SMS alerts can be congured from the network settings web page in the
MSView TriStar MPPT wizard.
View Logged Data
The TS-MPPT-600V-TR logs up to 200 days* of daily data. The controller always logs the stan-
dard values listed below. Using MSView, the controller can be congured to log additional option-
al values each day. The maximum number of days that can be stored decreases as the number
of logged values increases.
Standard Values
• Minimum Battery Voltage
• Maximum Battery Voltage
• Daily Events (Equalize triggered, Entered Float, Alarm/Fault occurred, Controller Reset)
• Faults / Alarms - recorded only if a fault or alarm occurs that day
Optional Values
• Maximum Array Voltage
• Maximum Power Output
• Charge Amp-hours
• Charge Watt-hours
• Minimum/Maximum Battery Temperature
• Charge stage regulation timers for Absorption, Float, Equalize
* logging only standard values
SNMP
For telecom and industrial applications that require SNMP monitoring of deployed systems, the
TriStar MPPT will behave as an SNMP agent and supports the following commands:
TRAP
GET
GETNEXT
A link to the agent Management Information Base le (*.MIB) is available on the
TS-MPPT-600V-TR Live View Network Settings page.