Installation Guide

67TriStar MPPT Operator’s Manual
66
Specications
Efciency
TriStar MPPT 12 Volt Efficiency
output power (Watts)
efficiency (%)
98
97
96
95
94
93
92
91
90
89
50 100 150 200 250 300 350 400 450 500 550 600 650 700 750
0
88
16.5 Vmp
13 Vmp
66 Vmp
98 Vmp
Battery @ 12.8 V, 25 C ambient, rmware ver. 08 or later
TriStar MPPT 24 Volt Efficiency
output power (Watts)
efficiency (%)
99
98
97
96
95
94
93
92
91
90
100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500
0
89
33 Vmp
66 Vmp
98 Vmp
26 Vmp
Battery @ 25.6 V, 25 C ambient, rmware ver. 08 or later
TriStar MPPT 48 Volt Efficiency
output power (Watts)
efficiency (%)
100
99
98
97
96
95
94
93
92
91
200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000
0
90
52 Vmp
66 Vmp
83 Vmp
98 Vmp
Battery @ 51.2 V, 25 C ambient, rmware ver. 08 or later