Installation Guide

28 Operation
Equalize Start/Stop
Use this screen to initiate and terminate a manual equaliza-
tion charge. Holding the right arrow for 2 seconds will start the
equalization charge. Hold again for 2 seconds and equaliza-
tion will stop. The SOC LEDs on the TriStar controller should
ashtheequalizestart/stopsequenceasdenedinthe
controller Operator’s Manual.
NOTE:
If the TriStar is congured for a battery type that does
not have an equalize charge stage and an equalize
operation is requested on the meter, the meter will
display an “Error!” message indicating that an equal-
ization charge cannot occur.
This Manual Operation screen will only be displayed for
TriStars in Charge Control mode.
Load On/Off
Press and hold the right arrow push-button for 2 seconds to
toggle the load on or off. If the controller is in low voltage
disconnect (LVD), the load will reconnect for 10 minutes and
then turn off automatically. There is no limit to the number of
load reconnects in LVD.
This Manual Operation screen will only be displayed for
TriStars in Load Control mode.
Battery Service (Diagnostics Menu)
If battery service was performed early, this screen can be used
to reset the service interval back to zero. The battery service
reminder function is only enabled in custom settings.