Installation Guide

20 Installation
Example Network #1
E
M
ETER
H
U
B
E
M
E
TER
H
U
B
MeterBus Communication Hub
FOR INDOOR
USE ONLY
MODEL: HUB-1
FOR USE WITH
MORNINGSTAR
METERBUS NETWORKS
ONLY
TriStar
TS-RM-2
TriStar
1
2
Figure 3-3. A simple two TriStar system with Remote Meter.
• TriStar 1 provides power to both a hub and to a single Remote
Meter connected to Output Power Port A.
• TriStar 2 is connected to Port 1 on the Hub and is electrically
isolated from TriStar 1.
NOTE:
Electrical isolation protects controllers, cables, and
other system equipment from damaged due to poor or
disconnected system grounds.