Installation Guide
13TriStar Meter 2 Operator’s Manual
3.3 TS-RM-2 Install (1 TriStar)
The remote meter is designed to mount into a standard duplex
(2-gang)box,orushagainstawallorcabinetwithaproperly
sized hole. To install the remotely mounted meter to a single
TriStar:
1. Connect one end of the 30 meter cable to the TriStar
RJ-11 socket (or to the open meter socket if a TS-M-2 or
TS-M-2-600V is already mounted to the TriStar).
2. Looking at the back of the remote meter, connect the other
end of the cable to the left socket - see Figure 3.1 in Section
3.2.
3. Conrmthatthemeterisworkingbeforemounting.
4. Mount the meter to the wall or cabinet. If a 2-gang box is
not being used, cut a hole in the wall or cabinet sized per
the TS-RM-2 dimensions provided on the inside cover of this
manual.
NOTE:
Two remote meters can be installed if a TS-M-2 or
TS-M-2-600V meter is not attached to the TriStar
controller.