Installation Guide

EN-Rev IM/GN-AM-EN/A13 Copyright © November, 2018. Canadian Solar Inc.
20 
|
MOUNTING METHOD C: MOUNTING
METHODS WITH (SINGLE-AXIS TRACKER)
· Canadian Solar Inc. modules can be mounted on
single-axis trackers using center clamps or mounting
holes as described below. All the requirements of
the standard module installation manual and specic
tracker detailed installation instructions should apply.
· The following tracker manufacturers and types are
approved with Canadian Solar modules.
Mounting Rail
Use two insertion proles running perpendicularly to
the long side frame. An additional support bar should
be placed below the module. Use two clamps on the
support bar.
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
Module
Type
Compatible
Tracker
Mounting
Hardware
Maximum Load (Pa)
Reference Manual
(Version No.)
CS3U-P, CS3U-
MS, CS6U-P,
CS6U-M,
CS3W-P
ATI DuraTrack™HZ
Tracking System(V3)
Clamp Ear (V3)
Uplift load ≤
2400 Pa
Downforce load ≤
2400 Pa
DuraTrack™HZ Solar
Tracker Installation Guide
(January 2017, Rev. B-01)
CS3U-P, CS3U-
MS, CS6U-P
and CS6U-M
NEXTracker NX
Horizon
400 mm Short Rail
(mounting holes)
Uplift load ≤
2400 Pa
Downforce load ≤
2400 Pa
NEXTracker NX Horizon
2.3.1
Installation Manual
(PDM-000149 Rev. B)
CS3W-P
NEXTracker NX
Horizon
V2.3 Top Clamp Rails
Rail part No: 20899,
20934, 20907
Uplift load ≤
2400 Pa
Downforce load ≤
2400 Pa
NEXTracker NX Horizon
2.3.1
Installation Manual
(PDM-000149 Rev. B)
CS3U-P, CS3U-
MS, CS6U-P
and CS6U-M
NEXTracker NX
Horizon
V2.3 Top Clamp Rails
Rail part No: 20899,
20942, 20908
Uplift load ≤
2400 Pa
Downforce load ≤
2400 Pa
NEXTracker NX Horizon
2.3.1
Installation Manual
(PDM-000149 Rev. B)
CS3U-P
Arctech
single-axis tracker
Portrait two rows
3438 mm rail
(bolting method /
M8 bolt + M8 plain
washer (O.D. = 24
mm) /
1155 mm holes
position)
Rail drawing No:
CS2018002
Uplift load ≤
2400 Pa
Downforce load ≤
2400 Pa
SSMFIM-rev01
(SkySmart-Module Fixing