Installation Guide

EN-Rev IM/GN-AM-EN/A13 Copyright © November, 2018. Canadian Solar Inc.
18 
|
Use two insertion proles running parallel to the long
side frame.
Use two insertion proles running perpendicularly to
the long side frame.
Maximum Load:
Uplift load ≤ 2000 Pa
Downforce load ≤ 2000 Pa
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 4000 Pa
CS3K-P, CS3K-MS, CS6K-P, CS6K-M, CS6K-MS, CS6V-P, CS6V-M and CS6V-MS
Use two insertion proles running perpendicularly
to the long side frame. An additional support
bar should be placed below the module. Use two
clamps on the support bar.
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
Use two insertion proles running parallel to the long
side frame.
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa
Use two insertion proles running perpendicularly to
the long side frame.
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 4000 Pa
CS6A-P, CS6A-M, CS6VL-MS and CS6A-MS