Installation Guide

MORNINGSTAR CORPORATION 35
3.0
34
3.0 INSTALLATION
Figure 6. Solar input wiring.
12 Volt
MODULE
12 Volt
MODULE
12 Volt
MODULE
SOLAR
POSITIVE (+)
SOLAR
NEGATIVE (-)
(+)
(+)
(+)
(-)
(-)
(
-
)
36 V NOMINAL MAX.
EARTH
GROUND
Connect the solar module(s) to the SS-MPPT. Refer to the
wire gauge chart on page 65 of this manual for correct wire
sizing.
If required, the negative solar connection may be
earth grounded. Use appropriate gauge wire and proper
grounding methods for the installation site.
Step 4: Optional Accessories
Install the Remote Temperature Sensor and Remote
Meter (both purchased separately) if required. Refer to the
instructions provided with each accessory for detailed
installation procedures.
WARNING: Risk of Fire.
If no Remote Temperature Sensor (RTS) is
connected, use the SunSaver-MPPT within 3m (10 ft) of the
batteries. Internal temperature compensation will be used
if the RTS is not connected. Use of the RTS is strongly
recommended.
AVERTISSEMENT
: Risque d’incendie.
Si non Capteur de température distant (RTS) est
connecté, utilisez le MPPT ProStar moins de 3m (10 pi) de
les batteries. Compensation de la température interne sera
utilisée si la RTS n’est pas connecté. Utilisation de la RTS
est fortement recommandé.