Specifications Sheet

05-2018
STC rated output (P
mpp
)* 330 Wp 335 Wp 340 Wp 345 Wp
Rated voltage (V
mpp
) at STC 37.15 V 37.26 V 37.33 V 37.38 V
Rated current (l
mpp
) at STC 8.89 A 9.00 A 9.11 A 9.23 A
Open circuit voltage (V
oc
) at STC 45.86 V 45.98 V 46.16 V 46.37 V
Short circuit current (I
sc
) at STC 9.52 A 9.57 A 9.62 A 9.67 A
Module eciency 17.1% 17.3% 17.6% 17.8%
Rated output (P
mpp
) at NOCT 230.4 Wp 233.9 Wp 237.4 Wp 240.9 Wp
Rated voltage (V
mpp
) at NOCT 33.92 V 34.01 V 34.10 V 34.15 V
Rated current (I
mpp
) at NOCT 6.79 A 6.88 A 6.96 A 7.05 A
Open circuit voltage (V
oc
) at NOCT 42.08 V 42.19 V 42.36 V 42.55 V
Short circuit current (I
sc
) at NOCT 7.37 A 7.40 A 7.44 A 7.48 A
Temperature coecient (P
mpp
) - 0.408%/°C
Temperature coecient (I
sc
) +0.050%/°C
Temperature coecient (V
oc
) - 0.311%/°C
Normal operating cell temperature
(NOCT)
46±2°C
Maximum system voltage (IEC/UL) 1000V
DC
or 1500V
DC
Number of diodes 3
Junction box IP rating IP 67
Maximum series fuse rating 15 A
ELECTRICAL SPECIFICATIONS
MECHANICAL SPECIFICATIONS
MODULE DIMENSION DETAILS
CURVE
PACKING SPECIFICATIONS
* Measurement tolerance +/- 3%
STC: Irradiance 1000W/m
2
, Cell Temperature 25°C, AM=1.5
NOCT: Irradiance 800W/m
2
, Ambient Temperature 20°C, AM=1.5, Wind Speed 1m/s
Outer dimensions (L x W x H)
1954 x 990 x 40 mm
76.93 x 38.98 x 1.57 in
Frame technology Aluminum, silver anodized
Module composition Glass / EVA / Backsheet (white)
Front glass thickness 3.2 mm / 0.13 in
Cable length (IEC/UL) 1150 mm / 45.28 in
Cable diameter (IEC/UL) 4 mm² / 12 AWG
Maximum mechanical test load 6000 Pa
Fire performance (IEC/UL) Class C (IEC) or Type 1 (UL)
Connector type (IEC/UL) MC4 compatible
Weight (module only) 21.8 kg / 48.06 lbs
Packing unit 27 pcs / box
Weight of packing unit
(for 40‘HQ container)
634 kg / 1398 lbs
Number of modules per
40‘HQ container
648 pcs
Tolerance +/- 1.0kg
Subject to sales contract
Option: 900(+) /600(-) mm for dened projects in advance.
Refer to Astronergy Crystalline Silicon PV Module Installation Manual or contact technical department.
Maximum Mechanical Test Load=1.5×Maximum Mechanical Design Load.
© Chint Solar (Zhejiang) Co., Ltd. Reserves the right of nal interpretation. please contact our company to use the latest version for contract.
40 mm/0.131 feet
32 mm/0.105 feet
11 mm/0.036 feet
40 mm/0.131 feet
A-A
40:1
18.5 mm/0.061 feet
7 mm/0.023 feet
11.5 mm/0.038 feet
3.5 mm/0.01
1
feet
I
10:1
200 mm/0.656 feet
946 mm/3.104 feet
990 mm/3.248 feet
A
A
488 mm/1.601 feet
190 mm/0.623 feet
299 mm/0.981 feet
1954 mm/6.411 feet
16-3.5 mm x 8.5 mm/
0.011 feet x 0.028 feet
Drainage hole
Ground hole
10-7 mm x11.5 mm /
0.023 feet x 0.038 feet
Mounting hole
1150 mm/3.773 feet
+
-