Installation Manual
To connect to the monitoring platform:
1. DesignateasingleinverterastheconnectionpointbetweentheRS485busandtheSolarEdge
monitoringplatform.Thisinverterwillserveasthemasterinverter.
2. ConnectthemastertotheSolarEdgemonitoringplatformviatheLANorZigBeecommunication
option.
To configure the RS485 communication bus:
Allinvertersareconfiguredbydefaultasslaves.Ifreconfigurationisrequired:
1. MakesuretheON/OFFswitchisOFF.
2. TurnONtheACtotheinverterbyturningONthecircuitbreakeronthemaindistributionpanel.
WARNING!
ELECTRICAL SHOCK HAZARD. Do not touch uninsulated wires when the inverter cover is removed.
AVERTISSEMENT!
RISQUE D’ÉLECTROCUTION, ne touchez pas les fils non isolés lorsque le couvercle de l'onduleur est
retiré.
3.
Usetheinternalbuttonstoconfiguretheconnection(slightlytouchtheblacksquarebuttons).Toset
theinverterdesignatedasmaster,selectthefollowingintheLCDmenus:
l CommunicationèServerè LAN,ZigBee, orCDMA
l RS485-1Conf.è DeviceTypeè SolarEdge
l RS485-1Conf.èProtocolè Master
l RS485-1Conf.è Slave Detect
Thesystemstartsautomaticdetectionoftheslaveinvertersconnectedtothemasterinverter.The
invertershouldreportthecorrectnumberofslaves.Ifitdoesnot,verifytheconnectionsand
terminations.
4. Verifytheconnectionofthemastertothemonitoringplatform,asdescribedinthenextsection.
Verifying the Connection
Afterconnectingandconfiguringacommunicationoption,performthefollowingstepstocheckthat
theconnectiontothemonitoringserverhasbeensuccessfullyestablished.
1. Closetheinvertercover:Attachtheinvertercoverandsecureitbytighteningthescrewswitha
torqueof3.0N*m/2.2lb.*ft.Forpropersealing,firsttightenthecornerscrewsandthenthetwo
centralscrews.
2. IfnotalreadyON-TurnONtheACtotheinverterbyturningONthecircuitbreakeronthemain
distributionpanelandturningontheSafetySwitch.
3. WaitfortheinvertertoconnecttotheSolarEdgemonitoringplatform.Thismaytakeuptotwo
minutes.
AstatusscreensimilartothefollowingappearsontheLCDpanel:
V a c [ V ] V d c [ V ] P a c [ w ]
2 4 0 . 7 1 4 . 1 0 . 0
P _ O K : 0 0 0 / 0 0 0 < S _ O K >
- - - - - - - - - - - - - - - O F F
S_OK:IndicatesthattheconnectiontotheSolarEdgemonitoringplatformissuccessful.IfS_OKisnot
displayed,refertoTroubleshootingCommunicationonpage62.
Chapter 6: Setting Up Communication
Single Phase Inverter with HD-Wave Technology Installation MAN-01-00306-1.1
61