Installation Manual
Chapter 5: Commissioning the Installation
Thischapterdescribeshowtoactivatethesystem,pairthepoweroptimizerstotheinverterandverify
theproperfunctioningofthesystem.
Step 1: Activating the System
1. VerifythattheinverterON/OFFswitchisOFF.
2.
Ifnotalreadyremoved,removetheinvertercover:Opentheinvertercover’ssixAllenscrewsand
carefullypullthecoverhorizontallybeforeloweringit.
WARNING!
ELECTRICAL SHOCK HAZARD. Do not touch uninsulated wires when the inverter cover is
removed.
AVERTISSEMENT!
RISQUE D’ÉLECTROCUTION, ne touchez pas les fils non isolés lorsque le couvercle de l'onduleur
est retiré.
3.
Activatetheinverter:
a. VerifythatthecardS/NmatchestheinverterS/N.
b. Insertthecardintotheslotmarked"CARD"onthecommunicationboard.
c. TurnACON.
d.
LCDshows:Running Script...èDone!
Figure 19: Communication board and activation card
IfLCDshows:Failed:
l TurnACOFFandON(reset),andrepeattheactivationprocess.
l Usetheactivationcodethatappearsonthecertificationinverterlabeltomanuallyactivatethe
inverter.
l Iftheproblempersists,contactSolarEdgeSupport.
NOTE
Youcanusetheactivationcodethatappearsonthecertificationinverterlabeltoactivate
theinverterincaseofascripterrororamissingactivationcard.
4. Verifythattheinverterisconfiguredtothepropercountry:Presstheupordownbuttonsuntil
reachingtheIDstatusscreen:
D S P 1 / 2 : 1 . 0 2 1 0 / 1 . 0 0 3 4
C P U : 0 0 0 3 . 1 9 x x
C o u n t r y : U S A 1
Single Phase Inverter with HD-Wave Technology Installation MAN-01-00306-1.1
32
Chapter 5: Commissioning the Installation