Specifications

20 I MAN-Z180-000-(R00) © 2014 Owen Oil Tools All rights reserved
ZERO180 Gun System
5.9 Install a size -224 o-ring on the port hole and a size -216 o-ring on the port plug if not completed
prior. Apply a minimal amount of grease to threads and o-rings. Thread the port plug into the
tandem taking care not to knick or cut the wires and tighten.
Repeat steps 5.1 – 5.9 to arm each gun.
5.10 Perform any additional necessary actions to prepare gun string for conveyance in well.
6.0 Arming TCP Version
The ZERO180
®
gun system should be armed according to each company’s standard operating
procedures, gun assembly and ring head. While the guns themselves are unique, the assembly
method and connections external to the guns or gun string including the ring heads are not.