Specifications
20 I MAN-Z180-000-(R00) © 2014 Owen Oil Tools All rights reserved
ZERO180 Gun System
5.9 Install a size -224 o-ring on the port hole and a size -216 o-ring on the port plug if not completed
prior. Apply a minimal amount of grease to threads and o-rings. Thread the port plug into the
tandem taking care not to knick or cut the wires and tighten.
Repeat steps 5.1 – 5.9 to arm each gun.
5.10 Perform any additional necessary actions to prepare gun string for conveyance in well.
6.0 Arming TCP Version
The ZERO180
®
gun system should be armed according to each company’s standard operating
procedures, gun assembly and ring head. While the guns themselves are unique, the assembly
method and connections external to the guns or gun string including the ring heads are not.