Specifications
18 I MAN-Z180-000-(R00) © 2014 Owen Oil Tools All rights reserved
ZERO180 Gun System
5.0 Arming WL Version
The ZERO180
®
gun system should be armed according to each company’s standard operating
procedures. While the guns themselves are unique, the assembly method and connections external
to the guns or gun string are not. The ballistic connection of the detonator to det cord is unique and
will be covered in this section.
Warning:
Explosives are destructive by nature! Do not attempt
to disassemble or alter the detonator in any manner! Do not crush,
hammer, pinch, impact, pull wires or abuse the detonator or any
explosive!
Warning:
Be sure to follow safe operating practices as found in
API RP-67 in accordance with governmental regulations, company
policies and manufacturer’s recommendations!
The following steps as a minimum should be completed prior to commencing the arming procedures:
• HazardIdenticationandResolution
• Safety Meeting
• Stray Voltage Check
• Installation of grounding cables
• Check Fire through logging equipment (not perforating equipment)
• Power down all power sources and rf devices
• Remove safety key from inside of WL operating unit
• Attach perforating equipment to the WL cable
• Verify no voltage exists at the electrical connections of the gun
Warning:
Detonators should be removed from their packaging
and storage in the loading/arming area at the time of arming!
Always insert the detonator inside a safety tube after removal from
packaging and storage!