Technical information
12/01/02
70 / 21
80 / 27
90 / 32
Water
Water
Water
NOTE: Total Cycle Time = Freeze + Harvest.
Pressure data is recorded 5 minutes into the freeze cycle.
R-404A PERFORMANCE DATA
MODEL: KM-900MWH With SN M30501E and after
Supply Voltage: 208-230/60/3
Total Amperage (Compressor): 10.3A (9.7A)
Ice Production per cycle: 14.3 lbs. 720 pcs.
Water Consumption for water cooled Condenser: 70/50 (21/9) 909 Gal/24 hr:
90/70 1185 Gal/24 hr.
21
22
23
3.9
3.5
3.2
280
280
288
36
38
39
21
22
25
3.6
2.9
2.8
280
280
292
38
41
41
22
23
25
3.5
2.4
2.2
280
280
290
38
43
44
100 / 38
22
23
27
3..5
2.4
2.0
284
284
300
38
43
44
50 / 9
70 / 21
90 / 32
Water temp
F°C°
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
Kg=lbs.
x .454
Production
24 hours
(lbs.)
Ambient Temp (F°)
Pressure
High Side
Water
Cycle Time
Freeze
Cycle Time
Harvest
Pressure
Suction
50 / 9
70 / 21
90 / 32
91
846
830
787
833
808
754
814
778
694
830
790
740
12/20/03
2/20/03