Technical information
12/01/02
Ambient Temp (F°)
NOTE: Total Cycle Time = Freeze + Harvest. Pressure data is recorded 5 min
utes into the freeze cycle.
PERFORMANCE DATA
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
Water
Temp (F°)
70 / 21
80 / 27
90 / 32
Air Water
Air Water Air Water
624 / 283
576 / 261
420 / 236
32
35
42
3
3
3
270
291
309
50
51
52
541 / 245
520 / 236
483 / 219
37
38
42
3.4
3.3
3.2
280
280
284
48
48
49
587 / 266
513 / 233
463 / 210
35
40
47
3
3
3
286
318
330
50
51
53
525 / 238
492 / 223
452 / 195
38
40
45
3.3
3.1
3.1
280
280
286
48
49
50
576 / 261
460 / 209
406 / 184
35
44
51
3
2.9
2.9
291
340
356
51
52
54
Cycle Time
Freeze
Cycle Time
Harvest
Pressure
High Side
psig / kg/cm
2
G
Pressure
Suction
psig / kg/cm
2
G
Kg=lbs.
x .454
Production
24 hours
(lbs.)
MODEL: KM-630M_F-E & KM-630MAH-E
Supply Voltage: 220-240/50/ 1
Total Amperage (Compressor RLA): MAF-E / H-E 8.7A (7.1A) MWF-E 6.5A (5.9A) Ice Production per cycle: 14.3 lbs. 720 pcs.
Water consumption for water cooled condenser:
70/50 (21/ 9) 368 Gal/24 hr. 90/70 (32/21) 586 Gal/24 hr
.
520 / 236
469 / 213
429 / 195
38
42
46
3.3
2.9
2.9
280
280
285
48
49
50
100 / 38
Air Water
568 / 258
447 / 203
357 / 162
37
45
57
3
2.8
2.8
391
344
370
51
52
55
510 / 231
460 / 209
393 / 178
40
43
50
3.3
2.9
2.9
282
282
290
49
49
51
89
12/20/03
2/20/03