Technical information

12/01/02
MODEL: KML-600M_F / H
Supply Voltage: 208-230/60/1 (3 wire with neutr
al for 115V)
Total Amperage (Compressor RLA.): Air 11A (9.5A), Water 9A ( 8.3 A), Remote: 11. 9A (9.8 A) Production per cycle:
10lbs. 480 pcs.
Water consumption for water cooled cond: 70/50 (21/ 9) 458 Gal/24 hr. 90/70 (32/21) 844 Gal/24 hr.
70 / 21
80 / 27
90 / 32
NOTE: Total Cycle Time = Freeze + Harvest. Pressure data is recorded 5 minutes into the freez
e cycle
38
41
47
250
271
302
3.5
3.1
2.9
20
21
24
631
596
542
35
36
42
270
272
280
3.9
3.5
3.2
21
22
23
572
547
534
40
45
51
266
298
332
3.2
2.5
2.6
21
23
26
605
551
492
36
37
46
272
275
285
3.6
2.9
2.8
21
22
24
553
515
513
635
610
574
3.5
3.2
2.9
220
232
255
32
35
41
616
577
540
20
21
23
3.3
2.8
2.6
229
247
274
34
39
46
41
48
54
280
320
354
2.9
2.0
2.0
22
24
27
575
513
455
36
38
46
272
278
287
3.5
2.5
2.2
22
23
25
547
488
481
610
550
512
20
21
23
3.2
2.5
2.2
232
260
286
35
42
49
310
328
385
20
20
21
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
Water
Temp (F°)
Cycle Time
Freeze
Cycle Time
Harvest
Pressure
High Side
Pressure
Suction
Ambient Temp (F° / C°)
Kg=lbs.
x .454
Production
24 hours
(lbs.)
100 / 38
43
49
60
2.5
2.0
2.0
24
25
30
540
499
401
39
40
53
275
280
295
3.5
2.4
2.0
22
23
26
535
486
475
602
541
478
21
21
25
3.2
2.4
2.0
239
266
310
37
44
55
86
PERFORMANCE DATA
Air
Remote
Water
Air
Remote
Water
Air
Remote
Water
Air
Remote
Water
12/20/03
2/20/03