Technical information

12/01/02
70 / 21
80 / 27
90 / 32
Water
Water
Water
NOTE: Total Cycle Time = Freeze + Harvest.
Pressure data is recorded 5 minutes into the freeze cycle.
R-404A PERFORMANCE DATA
MODEL: KML-450MWH With SN M20531D and after
Supply Voltage: 115/60/1
Total Amperage (Compressor): 12A (10.6A)
Ice Production per cycle: 6.6 lbs. 360 pcs.
Water Consumption for water cooled Condenser: 70/50 (21/9) 547 Gal/24 hr:
90/70 728 Gal/24 hr.
20
21
22
3.5
3.1
2.9
280
280
286
47
48
52
20
21
23
3.2
2.5
2.6
280
280
289
47
48
55
21
22
24
3.1
2.0
2.0
280
280
290
48
49
55
100 / 38
21
22
25
3.2
2.0
2.0
283
284
295
50
50
60
50 / 9
70 / 21
90 / 32
Water temp
F°C°
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
Kg=lbs.
x .454
Production
24 hours
(lbs.)
Ambient Temp (F°)
Pressure
High Side
Water
Cycle Time
Freeze
Cycle Time
Harvest
Pressure
Suction
50 / 9
70 / 21
90 / 32
82
433
426
402
428
417
385
417
402
354
426
409
380
12/20/03
2/20/03