Technical information
12/01/02
KM INSTALLATION
GENERAL -
The ice machine is not intended for outdoor use.
OPERATING CONDITIONS - ALL MODELS
ITEM
MODEL
RANGE
Voltage Range 115V units 104 - 127V.
208-230 V units 187 - 264 V.
220-240 or 230V 198 - 254V.
Ambient Temperature All 45 - 100 Deg. F.
Remote Condenser -20 - 122 Deg. F.
Water Supply Temperature All 45 - 90 Deg. F.
Water Supply Pressure All 10 -113 PSIG
Allow 6" clearance at rear, sides, and top for proper air
circulation and ease of maintenance or service. 20" top
clearance for F/DCM.
PLUMBING REQUIREMENTS -
Water Supply:
On KM units the water supply line size is critical due to
the water assisted harvest and the use of a ported inlet
water valve solenoid.
MODEL
Line Size
Fitting Size
KM-150 - KM-900 3/8" OD 1/2 FPT
KM-1300 - KM-2400 1/2" OD 1/2 FPT
All F/DCM 3/8" OD 1/2 FPT
*Water cooled condenser units require two separate
supplies sized as per list above.
Drain:
MODEL
Line Size
Fitting Size
All Bins 3/4" OD 3/4 FPT
All KM/KML’s 3/4" OD 3/4 FPT
Flakers 3/4" OD 3/4 FPT*
DCM 3/4" OD 3/4 FPT*
*Some models have 2 drain outlets.
Water Cooled Condenser outlet:
KM-150BWF, KM-250BWF, KM-1600SWH,
KM-1600SWH3, KM-2000SWH3 have 1/2” FPT outlet.
All other KM models, All KML, All Flaker, All DCM have 3/8”
FPT outlet.
8
12/20/03
2/20/03