Technical information

12/01/02
Ambient Temp (F°)
MODEL: KM-150B_F- E
Supply Voltage: 220-240/50/1
Total Amperage (Compressor RLA): BAF-E 5A (3.8A) BWF-E: 5.5A (3.8A) Ice Production per cycle: 2.6 Lbs, 130 pcs.
Water Consumption for water cooled Condenser: 70/50 (21/9) 132 Gal/24 hr:
90/70 (32/21) 243 Gal/24 hr.
NOTE: Total Cycle Time = Freeze + Harvest. Pressure data is recorded 5 minutes into the freez
e cycle.
R-404A PERFORMANCE DATA
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
Water
Temp (F°)
70 / 21
80 / 27
90 / 32
Air Water
Air Water Air Water
138 / 63
127 / 58
114 / 52
25
28
33
3
3
3
260 / 18.3
281 / 19.7
303 / 21.3
45 / 3.2
46 / 3.2
47 / 3.3
150 / 68
141 / 64
129 / 59
22
24
26
3.2
3
3
280 / 19.7
281 / 19.8
284 / 20.0
45 / 3.2
46 / 3.2
48 / 3.4
130 / 59
113 / 51
101 / 46
27
32
37
3
3
3
276 / 19.4
308 / 21.6
326 / 23.0
46 / 3.2
47 / 3.3
48 / 3.4
143 / 65
129 / 59
118 / 54
23
26
29
3
3
3
46 / 3.2
47 / 3.3
49 / 3.5
127 / 58
101 / 46
88 / 40
28
35
41
3
3
2.5
281 / 19.7
330 / 23.2
351 / 24.7
46 / 3.2
47 / 3.4
49 / 3.4
141 / 64
119 / 54
108 / 49
24
28
30
3
3
3
281 / 19.8
285 / 20.0
288 / 20.2
46 / 3.2
48 / 3.4
50 / 3.5
281 / 19.8
283 / 19.9
286 / 20.1
Kg=lbs.
x .454
Production
24 hours
(lbs./kg.)
Cycle Time
Freeze
Cycle Time
Harvest
Pressure
High Side
Pressure
Suction
100 / 38
Air Water
74
125 / 57
98 / 44
76 / 34
29
36
46
3
3
2.5
282 / 19.9
335 / 23.2
370 / 26.0
46 / 3.2
47 / 3.4
50 / 3.5
139 / 63
116 / 53
97 / 44
25
29
33
3
3
2.7
282 / 19.8
286 / 20.1
290 / 20.4
46 / 3.2
48 / 3.4
52 / 3.7
psig / kg/cm
2
G
psig / kg/cm
2
G
12/20/03
2/20/03