Technical information

12/01/02
MODEL: KM-150B_F
Supply Voltage: 115-120/60/1
Total Amperage (Compressor RLA): BAF 8A (6A) BWF: 7.5A (6A) Ice Production per cycle: 2.6 Lbs, 130 pcs.
Water Consumption for water cooled Condenser: 70/50 (21/9) 134 Gal/24 hr:
90/70 (32/21) 326 Gal/24 hr.
NOTE: Total Cycle Time = Freeze + Harvest. Pressure data is recorded 5 minutes into the fre
eze
cycle.
R-404A PERFORMANCE DATA
70 / 21
80 / 27
90 / 32 100 / 38
Air Water
Air Water Air Water
Air Water
150
137
124
25
26
28
3.5
3
3
215
230
230
35
37
38
141
129
122
25
26
29
3.3
3
3
278
279
282
48
48
49
135
122
108
30
32
35
3
3
3
245
250
265
36
38
38
134
113
112
26
29
32
3
3
3
278
279
284
48
49
50
124
114
100
35
34
40
3
3
3
260
254
275
37
38
38
130
100
96
26
31
33
3
3
3
279
280
284
48
49
50
100
97
95
38
39
43
3
3
3
305
315
310
38
38
39
Kg=lbs.
x .454
Production
24 hours
(lbs.)
Cycle Time
Freeze
Cycle Time
Harvest
Pressure
High Side
Pressure
Suction
Ambient Temp (F°)
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
50 / 9
70 / 21
90 / 32
Water
Temp (F°)
73
128
99
93
27
31
36
3
3
2.8
280
281
288
49
49
51
12/20/03
2/20/03